    <description>&lt;P&gt;Is there a way to monitor power supply redundancy by SNMP?&lt;/P&gt;
&lt;P&gt;I found this, but these values are not a SNMP object.&lt;/P&gt;
&lt;P&gt;&lt;A href="https://knowledgebase.paloaltonetworks.com/KCSArticleDetail?id=kA10g000000ClbfCAC" target="_blank"&gt;https://knowledgebase.paloaltonetworks.com/KCSArticleDetail?id=kA10g000000ClbfCAC&lt;/A&gt;&lt;/P&gt;
&lt;P&gt;similar to this; these values don't exit on my PA-440.&lt;/P&gt;
&lt;P&gt;&lt;A href="https://live.paloaltonetworks.com/t5/general-topics/snmp-monitoring-on-pa3250-psu/td-p/417040" target="_blank"&gt;https://live.paloaltonetworks.com/t5/general-topics/snmp-monitoring-on-pa3250-psu/td-p/417040&lt;/A&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;all other SNMP is working; I just miss monitoring the power.&lt;/P&gt;</description>
    <pubDate>Fri, 19 Jan 2024 13:48:43 GMT</pubDate>
    <dc:creator>FloriReus</dc:creator>
    <dc:date>2024-01-19T13:48:43Z</dc:date>
    <item>
      <title>Monitor Power Supply of PA-400 by SNMP</title>
      <link>https://live.paloaltonetworks.com/t5/general-topics/monitor-power-supply-of-pa-400-by-snmp/m-p/573629#M115326</link>
      <description>&lt;P&gt;Is there a way to monitor power supply redundancy by SNMP?&lt;/P&gt;
&lt;P&gt;I found this, but these values are not a SNMP object.&lt;/P&gt;
&lt;P&gt;&lt;A href="https://knowledgebase.paloaltonetworks.com/KCSArticleDetail?id=kA10g000000ClbfCAC" target="_blank"&gt;https://knowledgebase.paloaltonetworks.com/KCSArticleDetail?id=kA10g000000ClbfCAC&lt;/A&gt;&lt;/P&gt;
&lt;P&gt;similar to this; these values don't exit on my PA-440.&lt;/P&gt;
&lt;P&gt;&lt;A href="https://live.paloaltonetworks.com/t5/general-topics/snmp-monitoring-on-pa3250-psu/td-p/417040" target="_blank"&gt;https://live.paloaltonetworks.com/t5/general-topics/snmp-monitoring-on-pa3250-psu/td-p/417040&lt;/A&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;all other SNMP is working; I just miss monitoring the power.&lt;/P&gt;</description>
      <pubDate>Fri, 19 Jan 2024 13:48:43 GMT</pubDate>
      <guid>https://live.paloaltonetworks.com/t5/general-topics/monitor-power-supply-of-pa-400-by-snmp/m-p/573629#M115326</guid>
      <dc:creator>FloriReus</dc:creator>
      <dc:date>2024-01-19T13:48:43Z</dc:date>
    </item>
    <item>
      <title>Re: Monitor Power Supply of PA-400 by SNMP</title>
      <link>https://live.paloaltonetworks.com/t5/general-topics/monitor-power-supply-of-pa-400-by-snmp/m-p/574073#M115397</link>
      <description>&lt;P&gt;Hi &lt;a href="https://live.paloaltonetworks.com/t5/user/viewprofilepage/user-id/239497"&gt;@FloriReus&lt;/a&gt; ,&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&lt;SPAN&gt;The power supply status monitoring via SNMP is only supported on certain platforms (like the PA-7000 platform). &lt;/SPAN&gt;&lt;/P&gt;
&lt;P&gt;&lt;SPAN&gt;Other platforms are not supported yet.&lt;/SPAN&gt;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&lt;SPAN&gt;For state of power source, ENTITY-STATE-MIB can be used.&lt;BR /&gt;For example. “snmpwalk -On -v2c -c public .1.3.6.1.2.1.131.1.1.1.ID*”&lt;BR /&gt;&lt;BR /&gt;This oid shows state of power supply module and its alarm state ... however it might not be implemented in the PA-400 series.&lt;/SPAN&gt;&lt;BR style="box-sizing: border-box; color: #181818; font-family: -apple-system, 'system-ui', 'Segoe UI', Roboto, Helvetica, Arial, sans-serif, 'Apple Color Emoji', 'Segoe UI Emoji', 'Segoe UI Symbol'; font-size: 12px; font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: start; text-indent: 0px; text-transform: none; widows: 2; word-spacing: 0px; -webkit-text-stroke-width: 0px; white-space: normal; background-color: #ffffff; text-decoration-thickness: initial; text-decoration-style: initial; text-decoration-color: initial;" /&gt;&lt;BR style="box-sizing: border-box; color: #181818; font-family: -apple-system, 'system-ui', 'Segoe UI', Roboto, Helvetica, Arial, sans-serif, 'Apple Color Emoji', 'Segoe UI Emoji', 'Segoe UI Symbol'; font-size: 12px; font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: start; text-indent: 0px; text-transform: none; widows: 2; word-spacing: 0px; -webkit-text-stroke-width: 0px; white-space: normal; background-color: #ffffff; text-decoration-thickness: initial; text-decoration-style: initial; text-decoration-color: initial;" /&gt;&lt;SPAN&gt;Upon checking, there are few Feature Requests reported already on these SNMP MIBs. Here are FR IDs:&lt;/SPAN&gt;&lt;BR style="box-sizing: border-box; color: #181818; font-family: -apple-system, 'system-ui', 'Segoe UI', Roboto, Helvetica, Arial, sans-serif, 'Apple Color Emoji', 'Segoe UI Emoji', 'Segoe UI Symbol'; font-size: 12px; font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: start; text-indent: 0px; text-transform: none; widows: 2; word-spacing: 0px; -webkit-text-stroke-width: 0px; white-space: normal; background-color: #ffffff; text-decoration-thickness: initial; text-decoration-style: initial; text-decoration-color: initial;" /&gt;&lt;BR style="box-sizing: border-box; color: #181818; font-family: -apple-system, 'system-ui', 'Segoe UI', Roboto, Helvetica, Arial, sans-serif, 'Apple Color Emoji', 'Segoe UI Emoji', 'Segoe UI Symbol'; font-size: 12px; font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: start; text-indent: 0px; text-transform: none; widows: 2; word-spacing: 0px; -webkit-text-stroke-width: 0px; white-space: normal; background-color: #ffffff; text-decoration-thickness: initial; text-decoration-style: initial; text-decoration-color: initial;" /&gt;&lt;SPAN&gt;FR ID: 1822&lt;/SPAN&gt;&lt;BR style="box-sizing: border-box; color: #181818; font-family: -apple-system, 'system-ui', 'Segoe UI', Roboto, Helvetica, Arial, sans-serif, 'Apple Color Emoji', 'Segoe UI Emoji', 'Segoe UI Symbol'; font-size: 12px; font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: start; text-indent: 0px; text-transform: none; widows: 2; word-spacing: 0px; -webkit-text-stroke-width: 0px; white-space: normal; background-color: #ffffff; text-decoration-thickness: initial; text-decoration-style: initial; text-decoration-color: initial;" /&gt;&lt;SPAN&gt;FR ID: 2276&lt;/SPAN&gt;&lt;BR style="box-sizing: border-box; color: #181818; font-family: -apple-system, 'system-ui', 'Segoe UI', Roboto, Helvetica, Arial, sans-serif, 'Apple Color Emoji', 'Segoe UI Emoji', 'Segoe UI Symbol'; font-size: 12px; font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: start; text-indent: 0px; text-transform: none; widows: 2; word-spacing: 0px; -webkit-text-stroke-width: 0px; white-space: normal; background-color: #ffffff; text-decoration-thickness: initial; text-decoration-style: initial; text-decoration-color: initial;" /&gt;&lt;SPAN&gt;FR ID: 4873&lt;/SPAN&gt;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&lt;SPAN&gt;Please reach out to your sales engineer to vote in favor of making this available in future software releases.&lt;/SPAN&gt;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&lt;SPAN&gt;Kind regards,&lt;/SPAN&gt;&lt;/P&gt;
&lt;P&gt;&lt;SPAN&gt;-Kim.&lt;/SPAN&gt;&lt;/P&gt;</description>