    <description>&lt;HTML&gt;&lt;HEAD&gt;&lt;/HEAD&gt;&lt;BODY&gt;&lt;P&gt;Hi,&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;the customer is looking for a redundant ports as there looking for a cross connection between two different switches.&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;is this possible? etherchannel/aggregate port configuration doesn't solve that issue as aggregate port goes in the same switch only.&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;Please suggest a way to resolve this.&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;Thanks &amp;amp; Regards&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;Nitesh&lt;/P&gt;&lt;/BODY&gt;&lt;/HTML&gt;</description>
    <pubDate>Tue, 09 Sep 2014 10:18:32 GMT</pubDate>
    <dc:creator>NiteshS</dc:creator>
    <dc:date>2014-09-09T10:18:32Z</dc:date>
    <item>
      <title>Redundant Ports</title>
      <link>https://live.paloaltonetworks.com/t5/general-topics/redundant-ports/m-p/10999#M8113</link>
      <description>&lt;HTML&gt;&lt;HEAD&gt;&lt;/HEAD&gt;&lt;BODY&gt;&lt;P&gt;Hi,&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;the customer is looking for a redundant ports as there looking for a cross connection between two different switches.&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;is this possible? etherchannel/aggregate port configuration doesn't solve that issue as aggregate port goes in the same switch only.&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;Please suggest a way to resolve this.&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;Thanks &amp;amp; Regards&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;Nitesh&lt;/P&gt;&lt;/BODY&gt;&lt;/HTML&gt;</description>
      <pubDate>Tue, 09 Sep 2014 10:18:32 GMT</pubDate>
      <guid>https://live.paloaltonetworks.com/t5/general-topics/redundant-ports/m-p/10999#M8113</guid>
      <dc:creator>NiteshS</dc:creator>
      <dc:date>2014-09-09T10:18:32Z</dc:date>
    </item>
    <item>
      <title>Re: Redundant Ports</title>
      <link>https://live.paloaltonetworks.com/t5/general-topics/redundant-ports/m-p/11000#M8114</link>
      <description>&lt;HTML&gt;&lt;HEAD&gt;&lt;/HEAD&gt;&lt;BODY&gt;&lt;P&gt;Hi Nitesh&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;if your switch supports spanning portgroups/aggregates across different chassis in a stack, you can solve this issue with an aggregate port group &lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;If you are unable to stack your switches, you could try setting multiple ports in L2 mode&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;regards&lt;/P&gt;&lt;P&gt;Tom&lt;/P&gt;&lt;/BODY&gt;&lt;/HTML&gt;</description>
      <pubDate>Tue, 09 Sep 2014 11:16:39 GMT</pubDate>
      <guid>https://live.paloaltonetworks.com/t5/general-topics/redundant-ports/m-p/11000#M8114</guid>
      <dc:creator>reaper</dc:creator>
      <dc:date>2014-09-09T11:16:39Z</dc:date>
    </item>
    <item>
      <title>Re: Redundant Ports</title>
      <link>https://live.paloaltonetworks.com/t5/general-topics/redundant-ports/m-p/11001#M8115</link>
      <description>&lt;HTML&gt;&lt;HEAD&gt;&lt;/HEAD&gt;&lt;BODY&gt;&lt;P&gt;hence you are saying we will do the following&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;1. Create a VLAN&lt;/P&gt;&lt;P&gt;2. Create a VLAN SVI and assign this to zone and vr&lt;/P&gt;&lt;P&gt;3. assign multiple ports in the same vlan&lt;/P&gt;&lt;P&gt;4. connect to the FW port to different switch and let spanning-tree on the switch do the blocking of the port.&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;Regards,&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;Nitesh&lt;/P&gt;&lt;/BODY&gt;&lt;/HTML&gt;</description>
      <pubDate>Tue, 09 Sep 2014 11:45:54 GMT</pubDate>
      <guid>https://live.paloaltonetworks.com/t5/general-topics/redundant-ports/m-p/11001#M8115</guid>
      <dc:creator>NiteshS</dc:creator>
      <dc:date>2014-09-09T11:45:54Z</dc:date>
    </item>
    <item>
      <title>Re: Redundant Ports</title>
      <link>https://live.paloaltonetworks.com/t5/general-topics/redundant-ports/m-p/11002#M8116</link>
      <description>&lt;HTML&gt;&lt;HEAD&gt;&lt;/HEAD&gt;&lt;BODY&gt;&lt;P&gt;Hi Nitesh,&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;You are almost correct. Follow bellow instructions.&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P style="font-family: 'Helvetica Neue', Helvetica, Arial, 'Lucida Grande', sans-serif; color: #3b3b3b;"&gt;&lt;SPAN style="padding: 0 0 1px; border-bottom-style: solid; border-bottom-color: #003366; font-weight: inherit; font-style: inherit; font-family: inherit; text-decoration: underline; color: #003366; background: none 0% 50% repeat scroll transparent;"&gt;1&lt;/SPAN&gt;.) Created new VLAN&lt;/P&gt;&lt;P style="font-family: 'Helvetica Neue', Helvetica, Arial, 'Lucida Grande', sans-serif; color: #3b3b3b;"&gt;2.) Created new VLAN interface (with L3-forwarding enabled)&lt;/P&gt;&lt;P style="font-family: 'Helvetica Neue', Helvetica, Arial, 'Lucida Grande', sans-serif; color: #3b3b3b;"&gt;3.) Placed new VLAN interface into appropriate security zone (L3-Trust in my configuration)&lt;/P&gt;&lt;P style="font-family: 'Helvetica Neue', Helvetica, Arial, 'Lucida Grande', sans-serif; color: #3b3b3b;"&gt;4.) Assigned new VLAN interface an IP Address (192.168.&lt;SPAN style="padding: 0 0 1px; border-bottom-style: solid; border-bottom-color: #003366; font-weight: inherit; font-style: inherit; font-family: inherit; text-decoration: underline; color: #003366; background: none 0% 50% repeat scroll transparent;"&gt;1&lt;/SPAN&gt;.&lt;SPAN style="padding: 0 0 1px; border-bottom-style: solid; border-bottom-color: #003366; font-weight: inherit; font-style: inherit; font-family: inherit; text-decoration: underline; color: #003366; background: none 0% 50% repeat scroll transparent;"&gt;1&lt;/SPAN&gt;/24 in my config)&lt;/P&gt;&lt;P style="font-family: 'Helvetica Neue', Helvetica, Arial, 'Lucida Grande', sans-serif; color: #3b3b3b;"&gt;5.) Configured 2 firewall ports as "Layer 2" and placed them into the newly created VLAN from step #&lt;SPAN style="padding: 0 0 1px; border-bottom-style: solid; border-bottom-color: #003366; font-weight: inherit; font-style: inherit; font-family: inherit; text-decoration: underline; color: #003366; background: none 0% 50% repeat scroll transparent;"&gt;1&lt;/SPAN&gt;&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P style="font-family: 'Helvetica Neue', Helvetica, Arial, 'Lucida Grande', sans-serif; color: #3b3b3b;"&gt;Commit&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P style="font-family: 'Helvetica Neue', Helvetica, Arial, 'Lucida Grande', sans-serif; color: #3b3b3b;"&gt;On the switch side, I created a vlan in a Brocade switch with 3 access ports.&amp;nbsp; I also enabled spanning-tree in this VLAN.&amp;nbsp; Of the 3 ports, 2 go to the firewall and one to a test laptop. &lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P style="font-family: 'Helvetica Neue', Helvetica, Arial, 'Lucida Grande', sans-serif; color: #3b3b3b;"&gt;In this configuration, everything works fine!&amp;nbsp; It takes 30-45 seconds to fail over, and about 15s to fail back - which is expected for standard spanning-tree behavior.&lt;/P&gt;&lt;P style="font-family: 'Helvetica Neue', Helvetica, Arial, 'Lucida Grande', sans-serif; color: #3b3b3b;"&gt;&lt;/P&gt;&lt;P style="font-family: 'Helvetica Neue', Helvetica, Arial, 'Lucida Grande', sans-serif; color: #3b3b3b;"&gt;For more reference refer bellow documents.&lt;/P&gt;&lt;P style="font-family: 'Helvetica Neue', Helvetica, Arial, 'Lucida Grande', sans-serif; color: #3b3b3b;"&gt;&lt;A href="https://live.paloaltonetworks.com/message/18399"&gt;Re: Redundant links&lt;/A&gt;&lt;/P&gt;&lt;P style="font-family: 'Helvetica Neue', Helvetica, Arial, 'Lucida Grande', sans-serif; color: #3b3b3b;"&gt;&lt;A href="https://live.paloaltonetworks.com/thread/5297"&gt;interface failover on PA500&lt;/A&gt;&lt;/P&gt;&lt;P style="font-family: 'Helvetica Neue', Helvetica, Arial, 'Lucida Grande', sans-serif; color: #3b3b3b;"&gt;&lt;/P&gt;&lt;P style="font-family: 'Helvetica Neue', Helvetica, Arial, 'Lucida Grande', sans-serif; color: #3b3b3b;"&gt;Regards,&lt;/P&gt;&lt;P style="font-family: 'Helvetica Neue', Helvetica, Arial, 'Lucida Grande', sans-serif; color: #3b3b3b;"&gt;Hardik Shah&lt;/P&gt;&lt;/BODY&gt;&lt;/HTML&gt;</description>
      <pubDate>Tue, 09 Sep 2014 12:20:42 GMT</pubDate>
      <guid>https://live.paloaltonetworks.com/t5/general-topics/redundant-ports/m-p/11002#M8116</guid>
      <dc:creator>hshah</dc:creator>
      <dc:date>2014-09-09T12:20:42Z</dc:date>
    </item>
    <item>
      <title>Re: Redundant Ports</title>
      <link>https://live.paloaltonetworks.com/t5/general-topics/redundant-ports/m-p/11003#M8117</link>
      <description>&lt;HTML&gt;&lt;HEAD&gt;&lt;/HEAD&gt;&lt;BODY&gt;&lt;P&gt;Hello Nitesh,&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;A similar discussion thread for your reference: &lt;A href="https://live.paloaltonetworks.com/message/17153"&gt;interface failover on PA500&lt;/A&gt;&lt;/P&gt;&lt;P&gt;&lt;/P&gt;&lt;P&gt;Thanks&lt;/P&gt;&lt;/BODY&gt;&lt;/HTML&gt;</description>
      <pubDate>Tue, 09 Sep 2014 13:32:41 GMT</pubDate>
      <guid>https://live.paloaltonetworks.com/t5/general-topics/redundant-ports/m-p/11003#M8117</guid>
      <dc:creator>HULK</dc:creator>
      <dc:date>2014-09-09T13:32:41Z</dc:date>