<?xml version="1.0" encoding="UTF-8"?>
<rss xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:taxo="http://purl.org/rss/1.0/modules/taxonomy/" version="2.0">
  <channel>
    <title>topic Re: Engine error after reboot in General Topics</title>
    <link>https://live.paloaltonetworks.com/t5/general-topics/engine-error-after-reboot/m-p/187810#M96353</link>
    <description>&lt;P&gt;&lt;a href="https://live.paloaltonetworks.com/t5/user/viewprofilepage/user-id/38293"&gt;@deanm&lt;/a&gt; : By an unknown reason, one (or more) of the checkpoint files ( "*.chkp" ) exists but is empty (zero bytes). Try to locate and remove it ( it should be located at &amp;lt;MINEMELDROOT&amp;gt;/local/data ) &lt;/P&gt;</description>
    <pubDate>Sun, 19 Nov 2017 09:33:16 GMT</pubDate>
    <dc:creator>xhoms</dc:creator>
    <dc:date>2017-11-19T09:33:16Z</dc:date>
    <item>
      <title>Engine error after reboot</title>
      <link>https://live.paloaltonetworks.com/t5/general-topics/engine-error-after-reboot/m-p/187794#M96352</link>
      <description>&lt;P&gt;My Minemeld system is failing to start, giving an engine error. The last it,e in the log is&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;2017-11-18T17:38:06 (2843)launcher._run_chassis ERROR: Exception in chassis main procedure&lt;BR /&gt;Traceback (most recent call last):&lt;BR /&gt; File "/opt/minemeld/engine/0.9.44/local/lib/python2.7/site-packages/minemeld/run/launcher.py", line 53, in _run_chassis&lt;BR /&gt; c.configure(fts)&lt;BR /&gt; File "/opt/minemeld/engine/0.9.44/local/lib/python2.7/site-packages/minemeld/chassis.py", line 102, in configure&lt;BR /&gt; config=ftconfig.get('config', {})&lt;BR /&gt; File "/opt/minemeld/engine/0.9.44/local/lib/python2.7/site-packages/minemeld/ft/__init__.py", line 10, in factory&lt;BR /&gt; config=config&lt;BR /&gt; File "/opt/minemeld/engine/0.9.44/local/lib/python2.7/site-packages/minemeld/ft/basepoller.py", line 321, in __init__&lt;BR /&gt; super(BasePollerFT, self).__init__(name, chassis, config)&lt;BR /&gt; File "/opt/minemeld/engine/0.9.44/local/lib/python2.7/site-packages/minemeld/ft/base.py", line 206, in __init__&lt;BR /&gt; self.read_checkpoint()&lt;BR /&gt; File "/opt/minemeld/engine/0.9.44/local/lib/python2.7/site-packages/minemeld/ft/base.py", line 257, in read_checkpoint&lt;BR /&gt; if contents[0] == '{':&lt;BR /&gt;IndexError: string index out of range&lt;BR /&gt;Process Process-1:&lt;BR /&gt;Traceback (most recent call last):&lt;BR /&gt; File "/usr/lib/python2.7/multiprocessing/process.py", line 258, in _bootstrap&lt;BR /&gt; self.run()&lt;BR /&gt; File "/usr/lib/python2.7/multiprocessing/process.py", line 114, in run&lt;BR /&gt; self._target(*self._args, **self._kwargs)&lt;BR /&gt; File "/opt/minemeld/engine/0.9.44/local/lib/python2.7/site-packages/minemeld/run/launcher.py", line 53, in _run_chassis&lt;BR /&gt; c.configure(fts)&lt;BR /&gt; File "/opt/minemeld/engine/0.9.44/local/lib/python2.7/site-packages/minemeld/chassis.py", line 102, in configure&lt;BR /&gt; config=ftconfig.get('config', {})&lt;BR /&gt; File "/opt/minemeld/engine/0.9.44/local/lib/python2.7/site-packages/minemeld/ft/__init__.py", line 10, in factory&lt;BR /&gt; config=config&lt;BR /&gt; File "/opt/minemeld/engine/0.9.44/local/lib/python2.7/site-packages/minemeld/ft/basepoller.py", line 321, in __init__&lt;BR /&gt; super(BasePollerFT, self).__init__(name, chassis, config)&lt;BR /&gt; File "/opt/minemeld/engine/0.9.44/local/lib/python2.7/site-packages/minemeld/ft/base.py", line 206, in __init__&lt;BR /&gt; self.read_checkpoint()&lt;BR /&gt; File "/opt/minemeld/engine/0.9.44/local/lib/python2.7/site-packages/minemeld/ft/base.py", line 257, in read_checkpoint&lt;BR /&gt; if contents[0] == '{':&lt;BR /&gt;IndexError: string index out of range&lt;BR /&gt;2017-11-18T17:38:16 (2837)launcher.main ERROR: Exception initializing graph&lt;BR /&gt;Traceback (most recent call last):&lt;BR /&gt; File "/opt/minemeld/engine/0.9.44/local/lib/python2.7/site-packages/minemeld/run/launcher.py", line 284, in main&lt;BR /&gt; mbusmaster.wait_for_chassis(timeout=10)&lt;BR /&gt; File "/opt/minemeld/engine/0.9.44/local/lib/python2.7/site-packages/minemeld/mgmtbus.py", line 141, in wait_for_chassis&lt;BR /&gt; raise RuntimeError('Timeout waiting for chassis')&lt;BR /&gt;RuntimeError: Timeout waiting for chassis&lt;BR /&gt;2017-11-18T17:38:16 (2837)mgmtbus.checkpoint_graph INFO: checkpoint_graph called, checking current state&lt;BR /&gt;2017-11-18T17:38:16 (2837)mgmtbus.checkpoint_graph INFO: graph status None, checkpoint_graph ignored&lt;BR /&gt;Traceback (most recent call last):&lt;BR /&gt; File "/opt/minemeld/engine/current/bin/mm-run", line 11, in &amp;lt;module&amp;gt;&lt;BR /&gt; sys.exit(main())&lt;BR /&gt; File "/opt/minemeld/engine/0.9.44/local/lib/python2.7/site-packages/minemeld/run/launcher.py", line 284, in main&lt;BR /&gt; mbusmaster.wait_for_chassis(timeout=10)&lt;BR /&gt; File "/opt/minemeld/engine/0.9.44/local/lib/python2.7/site-packages/minemeld/mgmtbus.py", line 141, in wait_for_chassis&lt;BR /&gt; raise RuntimeError('Timeout waiting for chassis')&lt;BR /&gt;RuntimeError: Timeout waiting for chassis&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;The only change on my side was to apply am OS X update (running VMWare Fusion, Ubuntu v14)&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;thank you,&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;Mike&lt;/P&gt;</description>
      <pubDate>Sun, 19 Nov 2017 03:06:34 GMT</pubDate>
      <guid>https://live.paloaltonetworks.com/t5/general-topics/engine-error-after-reboot/m-p/187794#M96352</guid>
      <dc:creator>deanm</dc:creator>
      <dc:date>2017-11-19T03:06:34Z</dc:date>
    </item>
    <item>
      <title>Re: Engine error after reboot</title>
      <link>https://live.paloaltonetworks.com/t5/general-topics/engine-error-after-reboot/m-p/187810#M96353</link>
      <description>&lt;P&gt;&lt;a href="https://live.paloaltonetworks.com/t5/user/viewprofilepage/user-id/38293"&gt;@deanm&lt;/a&gt; : By an unknown reason, one (or more) of the checkpoint files ( "*.chkp" ) exists but is empty (zero bytes). Try to locate and remove it ( it should be located at &amp;lt;MINEMELDROOT&amp;gt;/local/data ) &lt;/P&gt;</description>
      <pubDate>Sun, 19 Nov 2017 09:33:16 GMT</pubDate>
      <guid>https://live.paloaltonetworks.com/t5/general-topics/engine-error-after-reboot/m-p/187810#M96353</guid>
      <dc:creator>xhoms</dc:creator>
      <dc:date>2017-11-19T09:33:16Z</dc:date>
    </item>
    <item>
      <title>Re: Engine error after reboot</title>
      <link>https://live.paloaltonetworks.com/t5/general-topics/engine-error-after-reboot/m-p/187818#M96354</link>
      <description>&lt;P&gt;Thanks, that worked!&lt;/P&gt;</description>
      <pubDate>Sun, 19 Nov 2017 16:46:59 GMT</pubDate>
      <guid>https://live.paloaltonetworks.com/t5/general-topics/engine-error-after-reboot/m-p/187818#M96354</guid>
      <dc:creator>deanm</dc:creator>
      <dc:date>2017-11-19T16:46:59Z</dc:date>
    </item>
    <item>
      <title>Re: Engine error after reboot</title>
      <link>https://live.paloaltonetworks.com/t5/general-topics/engine-error-after-reboot/m-p/304532#M96355</link>
      <description>&lt;P&gt;&lt;a href="https://live.paloaltonetworks.com/t5/user/viewprofilepage/user-id/6710"&gt;@xhoms&lt;/a&gt;&amp;nbsp;I am trying to change name MINEMELD from file view.html located in webui/www/app/login. However, changed name does not reflect on login page. It works when I open html page in browser.&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Can you please help?&lt;/P&gt;</description>
      <pubDate>Fri, 20 Dec 2019 12:08:45 GMT</pubDate>
      <guid>https://live.paloaltonetworks.com/t5/general-topics/engine-error-after-reboot/m-p/304532#M96355</guid>
      <dc:creator>Papajones</dc:creator>
      <dc:date>2019-12-20T12:08:45Z</dc:date>
    </item>