    <title>article What are the differences between PMTerminal and TPC? in PAM Self-Hosted Articles</title>
    <link>https://live.paloaltonetworks.com/t5/pam-self-hosted-articles/what-are-the-differences-between-pmterminal-and-tpc/ta-p/1429171</link>
    <description>&lt;H3&gt;Question&lt;/H3&gt;
TPC is the official replacement for PMTerminal. Between the two, differences exist, what are they?

&lt;H3&gt;Answer&lt;/H3&gt;
&lt;P&gt;The table below lists the main differences :&lt;BR /&gt;&amp;nbsp;&lt;/P&gt;
&lt;TABLE border="1" style="width: 500px;"&gt;&lt;THEAD&gt;&lt;TR&gt;&lt;TH colspan="1" rowspan="1" style="text-align: center;"&gt;Area&lt;/TH&gt;&lt;TH colspan="1" rowspan="1" style="text-align: center;"&gt;PMTerminal&lt;/TH&gt;&lt;TH colspan="1" rowspan="1" style="text-align: center;"&gt;TPC&lt;/TH&gt;&lt;/TR&gt;&lt;/THEAD&gt;&lt;TBODY&gt;&lt;TR&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;&lt;A href="https://docs.cyberark.com/Product-Doc/OnlineHelp/PAS/Latest/en/Content/SDK/TPC-plugin-migration-info.htm#DifferencesbetweenPMTerminalandTPC" target="_blank"&gt;SSH : Connection&lt;/A&gt;&lt;/TD&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;Spawn Plink Executable to interact with the target.&lt;/TD&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;Spawn command is not executed. Gather all information and then interact with the target​.&lt;/TD&gt;&lt;/TR&gt;&lt;TR&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;&lt;A href="https://docs.cyberark.com/Product-Doc/OnlineHelp/PAS/Latest/en/Content/SDK/TPC-plugin-migration-info.htm#DifferencesbetweenPMTerminalandTPC" target="_blank"&gt;SSH : Logon Prompts&lt;/A&gt;&lt;/TD&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;Uses prompts to interact with the target​.&lt;/TD&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;Does not any receive any prompts from the target​.&lt;BR /&gt;&lt;BR /&gt;Connection unsuccessful = full plugin logic fails (per default)​.​&lt;BR /&gt;&lt;BR /&gt;&lt;A href="https://docs.cyberark.com/Product-Doc/OnlineHelp/PAS/Latest/en/Content/SDK/TPC-process.htm#EnableTPCLogonPrompts" target="_blank"&gt;EnableTPCLogonPrompts&lt;/A&gt;&amp;nbsp;can be set to Yes if needed​.&lt;/TD&gt;&lt;/TR&gt;&lt;TR&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;&lt;A href="https://docs.cyberark.com/Product-Doc/OnlineHelp/PAS/Latest/en/Content/Plugins/Configure-SSH-features.htm#SSH" target="_blank"&gt;SSH : Fingerprints&lt;/A&gt;&lt;/TD&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;Plink has a built-in security mechanism that stores the fingerprint of the target​.&lt;/TD&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;Does not use Plink, TPC has its own logic​.&lt;/TD&gt;&lt;/TR&gt;&lt;TR&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;&lt;A href="https://docs.cyberark.com/Product-Doc/OnlineHelp/PAS/Latest/en/Content/SDK/TPC-plugin-migration-info.htm#Telnet" target="_blank"&gt;Telnet : Connection&lt;/A&gt;&lt;/TD&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;Can Spawn Telnet.&lt;/TD&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;Spawn command not executed, only used to determine the connection data.&lt;/TD&gt;&lt;/TR&gt;&lt;TR&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;&lt;A href="https://docs.cyberark.com/Product-Doc/OnlineHelp/PAS/Latest/en/Content/SDK/TPC-plugin-migration-info.htm#SendSlowandSendHuman" target="_blank"&gt;SendSlow and Send Human&lt;/A&gt;&lt;/TD&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;Sends prompts to the target one letter at a time.&lt;/TD&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;Sends all of the text in a prompt to the target at one time, significantly improving performance&amp;nbsp;(if too fast, &lt;A href="https://docs.cyberark.com/Product-Doc/OnlineHelp/PAS/Latest/en/Content/SDK/TPC-process.htm#Parameters" target="_blank"&gt;can still send one letter at a time&lt;/A&gt;)​.&lt;BR /&gt;&lt;BR /&gt;Also see &lt;A href="https://community.cyberark.com/s/article/CPM-TPC-SendHumanMin-SendHumanMax-usage" target="_blank"&gt;CPM - TPC - SendHumanMin\ SendHumanMax usage&lt;/A&gt;.&lt;/TD&gt;&lt;/TR&gt;&lt;TR&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;&lt;A href="https://docs.cyberark.com/Product-Doc/OnlineHelp/PAS/Latest/en/Content/SDK/TPC-plugin-migration-info.htm#Webconnections" target="_blank"&gt;Web Connections : authentication&lt;/A&gt;&lt;/TD&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;iMacros script used.&lt;/TD&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;iMacros can still be used​.&lt;BR /&gt;&lt;BR /&gt;​Recommended to use &lt;A href="https://docs.cyberark.com/Product-Doc/OnlineHelp/PAS/Latest/en/Content/Plugins/CPM_WebApplication.htm" target="_blank"&gt;Web applications for CPM framework&lt;/A&gt;​.&lt;/TD&gt;&lt;/TR&gt;&lt;TR&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;&lt;A href="https://docs.cyberark.com/Product-Doc/OnlineHelp/PAS/Latest/en/Content/SDK/TPC-plugin-migration-info.htm#Usingsecretsinscripts" target="_blank"&gt;Secrets in Scripts&lt;/A&gt;&lt;/TD&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;N/A&lt;/TD&gt;&lt;TD colspan="1" rowspan="1"&gt;
&lt;DIV style="text-align: center;"&gt;Encrypts all secrets and stores them in the process memory​.&lt;/DIV&gt;
&lt;DIV style="text-align: center;"&gt;&lt;BR /&gt;​Can remove encryption with EncryptSecret=No (not recommended)​.&lt;/DIV&gt;
&lt;/TD&gt;&lt;/TR&gt;&lt;TR&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;&lt;A href="https://docs.cyberark.com/Product-Doc/OnlineHelp/PAS/Latest/en/Content/SDK/TPC-plugin-migration-info.htm#Newline" target="_blank"&gt;New Line : CRLF Character&lt;/A&gt;&lt;/TD&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;Carriage Return character (ASCII 13, \r) in all cases.&lt;/TD&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;Uses the Carriage Return character only when running SSH or Telnet​.&lt;BR /&gt;&lt;BR /&gt;​In all other cases, TPC uses the Line Feed character (ASCII 10, \n).&lt;/TD&gt;&lt;/TR&gt;&lt;TR&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;&lt;A href="https://docs.cyberark.com/Product-Doc/OnlineHelp/PAS/Latest/en/Content/SDK/TPC-plugin-migration-info.htm#Newline" target="_blank"&gt;New Line : RegEx matching with \n&lt;/A&gt;&lt;/TD&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;When using Regex to match prompts returned from the target, \n will match any new line method.&lt;/TD&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;When using Regex to match prompts returned from the target, try to match \n to \n or \r\n&lt;/TD&gt;&lt;/TR&gt;&lt;TR&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;&lt;A href="https://docs.cyberark.com/Product-Doc/OnlineHelp/PAS/Latest/en/Content/SDK/TPC-plugin-migration-info.htm#Python" target="_blank"&gt;Python&lt;/A&gt;&lt;/TD&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;N/A&lt;/TD&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;​In order to have the output written to a location from where TPC can read the prompts, add the "-u" parameter when calling a Python script.&lt;/TD&gt;&lt;/TR&gt;&lt;TR&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;&lt;A href="https://docs.cyberark.com/Product-Doc/OnlineHelp/PAS/Latest/en/Content/SDK/TPC-plugin-migration-info.htm#Limitations" target="_blank"&gt;Known limitations&lt;/A&gt;&lt;/TD&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;Not relevant (not Idira supported anymore).&lt;/TD&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;​Cannot work with Mainframe with WC3270 (works fine with Mainframe with Telnet or SSH)​.&lt;BR /&gt;&lt;BR /&gt;TPC supports using one connection at a time (open a connection, close that connection, and then open a new connection)​.&lt;BR /&gt;&lt;BR /&gt;​When a new connection is established, if there are any open connections that were created prior to the new connection, they will be unavailable​.&lt;BR /&gt;&lt;BR /&gt;​Concurrent connections created by running multiple spawn or invoke commands are not supported​.&lt;BR /&gt;&lt;BR /&gt;Important Known Issues in the Idira Community:&lt;BR /&gt;&lt;BR /&gt;&lt;A href="https://community.cyberark.com/s/article/KI00015793" target="_blank"&gt;KI#00015793: TPC: Fix error content with special characters (force.com)&lt;/A&gt;&lt;BR /&gt;&lt;BR /&gt;&lt;A href="https://community.cyberark.com/s/article/KI00016251" target="_blank"&gt;KI#00016251: Unix SSH - Logon Failure Flows Are Not Executed&lt;/A&gt;&lt;BR /&gt;&lt;BR /&gt;&lt;A href="https://community.cyberark.com/s/article/KI00016307" target="_blank"&gt;KI#00016307: TPC: Does not read from output of previous command when using executable application (for example: PLINK)&lt;/A&gt;&lt;BR /&gt;&lt;BR /&gt;&lt;A href="https://community.cyberark.com/s/article/KI00017002" target="_blank"&gt;KI#00017002: Mutex Error - System.Threading.AbandonedMutexException: The wait completed due to an abandoned mutex.&lt;/A&gt;&lt;BR /&gt;&lt;BR /&gt;Review also the &lt;A href="https://community.cyberark.com/s/search-results#searchString%3D%26pageNum%3D1%26sortBy%3D_score%26orderBy%3Ddesc%26resultsPerPage%3D10%26pageSizeAdv%3D10%26exactPhrase%3D%26withOneOrMore%3D%26withoutTheWords%3D%26selectedType%3D%255B%257B%2522type%2522%253A%2522server_community___knowledge_article__kav___KB_Article_Type__c%2522%252C%2522filter%2522%253A%255B%2522Known%2520Issue%2522%255D%257D%255D%26smartFacets%3Dfalse" target="_blank"&gt;Known Issues&lt;/A&gt;&amp;nbsp;section of the Idira Community for updated content.&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;</description>
    <pubDate>Thu, 05 Nov 2026 19:53:25 GMT</pubDate>
    <dc:creator>CyberArkAlumni</dc:creator>
    <dc:date>2026-11-05T19:53:25Z</dc:date>
    <item>
      <title>What are the differences between PMTerminal and TPC?</title>
      <link>https://live.paloaltonetworks.com/t5/pam-self-hosted-articles/what-are-the-differences-between-pmterminal-and-tpc/ta-p/1429171</link>
      <description>&lt;H3&gt;Question&lt;/H3&gt;
TPC is the official replacement for PMTerminal. Between the two, differences exist, what are they?

&lt;H3&gt;Answer&lt;/H3&gt;
&lt;P&gt;The table below lists the main differences :&lt;BR /&gt;&amp;nbsp;&lt;/P&gt;
&lt;TABLE border="1" style="width: 500px;"&gt;&lt;THEAD&gt;&lt;TR&gt;&lt;TH colspan="1" rowspan="1" style="text-align: center;"&gt;Area&lt;/TH&gt;&lt;TH colspan="1" rowspan="1" style="text-align: center;"&gt;PMTerminal&lt;/TH&gt;&lt;TH colspan="1" rowspan="1" style="text-align: center;"&gt;TPC&lt;/TH&gt;&lt;/TR&gt;&lt;/THEAD&gt;&lt;TBODY&gt;&lt;TR&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;&lt;A href="https://docs.cyberark.com/Product-Doc/OnlineHelp/PAS/Latest/en/Content/SDK/TPC-plugin-migration-info.htm#DifferencesbetweenPMTerminalandTPC" target="_blank"&gt;SSH : Connection&lt;/A&gt;&lt;/TD&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;Spawn Plink Executable to interact with the target.&lt;/TD&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;Spawn command is not executed. Gather all information and then interact with the target​.&lt;/TD&gt;&lt;/TR&gt;&lt;TR&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;&lt;A href="https://docs.cyberark.com/Product-Doc/OnlineHelp/PAS/Latest/en/Content/SDK/TPC-plugin-migration-info.htm#DifferencesbetweenPMTerminalandTPC" target="_blank"&gt;SSH : Logon Prompts&lt;/A&gt;&lt;/TD&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;Uses prompts to interact with the target​.&lt;/TD&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;Does not any receive any prompts from the target​.&lt;BR /&gt;&lt;BR /&gt;Connection unsuccessful = full plugin logic fails (per default)​.​&lt;BR /&gt;&lt;BR /&gt;&lt;A href="https://docs.cyberark.com/Product-Doc/OnlineHelp/PAS/Latest/en/Content/SDK/TPC-process.htm#EnableTPCLogonPrompts" target="_blank"&gt;EnableTPCLogonPrompts&lt;/A&gt;&amp;nbsp;can be set to Yes if needed​.&lt;/TD&gt;&lt;/TR&gt;&lt;TR&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;&lt;A href="https://docs.cyberark.com/Product-Doc/OnlineHelp/PAS/Latest/en/Content/Plugins/Configure-SSH-features.htm#SSH" target="_blank"&gt;SSH : Fingerprints&lt;/A&gt;&lt;/TD&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;Plink has a built-in security mechanism that stores the fingerprint of the target​.&lt;/TD&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;Does not use Plink, TPC has its own logic​.&lt;/TD&gt;&lt;/TR&gt;&lt;TR&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;&lt;A href="https://docs.cyberark.com/Product-Doc/OnlineHelp/PAS/Latest/en/Content/SDK/TPC-plugin-migration-info.htm#Telnet" target="_blank"&gt;Telnet : Connection&lt;/A&gt;&lt;/TD&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;Can Spawn Telnet.&lt;/TD&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;Spawn command not executed, only used to determine the connection data.&lt;/TD&gt;&lt;/TR&gt;&lt;TR&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;&lt;A href="https://docs.cyberark.com/Product-Doc/OnlineHelp/PAS/Latest/en/Content/SDK/TPC-plugin-migration-info.htm#SendSlowandSendHuman" target="_blank"&gt;SendSlow and Send Human&lt;/A&gt;&lt;/TD&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;Sends prompts to the target one letter at a time.&lt;/TD&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;Sends all of the text in a prompt to the target at one time, significantly improving performance&amp;nbsp;(if too fast, &lt;A href="https://docs.cyberark.com/Product-Doc/OnlineHelp/PAS/Latest/en/Content/SDK/TPC-process.htm#Parameters" target="_blank"&gt;can still send one letter at a time&lt;/A&gt;)​.&lt;BR /&gt;&lt;BR /&gt;Also see &lt;A href="https://community.cyberark.com/s/article/CPM-TPC-SendHumanMin-SendHumanMax-usage" target="_blank"&gt;CPM - TPC - SendHumanMin\ SendHumanMax usage&lt;/A&gt;.&lt;/TD&gt;&lt;/TR&gt;&lt;TR&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;&lt;A href="https://docs.cyberark.com/Product-Doc/OnlineHelp/PAS/Latest/en/Content/SDK/TPC-plugin-migration-info.htm#Webconnections" target="_blank"&gt;Web Connections : authentication&lt;/A&gt;&lt;/TD&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;iMacros script used.&lt;/TD&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;iMacros can still be used​.&lt;BR /&gt;&lt;BR /&gt;​Recommended to use &lt;A href="https://docs.cyberark.com/Product-Doc/OnlineHelp/PAS/Latest/en/Content/Plugins/CPM_WebApplication.htm" target="_blank"&gt;Web applications for CPM framework&lt;/A&gt;​.&lt;/TD&gt;&lt;/TR&gt;&lt;TR&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;&lt;A href="https://docs.cyberark.com/Product-Doc/OnlineHelp/PAS/Latest/en/Content/SDK/TPC-plugin-migration-info.htm#Usingsecretsinscripts" target="_blank"&gt;Secrets in Scripts&lt;/A&gt;&lt;/TD&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;N/A&lt;/TD&gt;&lt;TD colspan="1" rowspan="1"&gt;
&lt;DIV style="text-align: center;"&gt;Encrypts all secrets and stores them in the process memory​.&lt;/DIV&gt;
&lt;DIV style="text-align: center;"&gt;&lt;BR /&gt;​Can remove encryption with EncryptSecret=No (not recommended)​.&lt;/DIV&gt;
&lt;/TD&gt;&lt;/TR&gt;&lt;TR&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;&lt;A href="https://docs.cyberark.com/Product-Doc/OnlineHelp/PAS/Latest/en/Content/SDK/TPC-plugin-migration-info.htm#Newline" target="_blank"&gt;New Line : CRLF Character&lt;/A&gt;&lt;/TD&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;Carriage Return character (ASCII 13, \r) in all cases.&lt;/TD&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;Uses the Carriage Return character only when running SSH or Telnet​.&lt;BR /&gt;&lt;BR /&gt;​In all other cases, TPC uses the Line Feed character (ASCII 10, \n).&lt;/TD&gt;&lt;/TR&gt;&lt;TR&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;&lt;A href="https://docs.cyberark.com/Product-Doc/OnlineHelp/PAS/Latest/en/Content/SDK/TPC-plugin-migration-info.htm#Newline" target="_blank"&gt;New Line : RegEx matching with \n&lt;/A&gt;&lt;/TD&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;When using Regex to match prompts returned from the target, \n will match any new line method.&lt;/TD&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;When using Regex to match prompts returned from the target, try to match \n to \n or \r\n&lt;/TD&gt;&lt;/TR&gt;&lt;TR&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;&lt;A href="https://docs.cyberark.com/Product-Doc/OnlineHelp/PAS/Latest/en/Content/SDK/TPC-plugin-migration-info.htm#Python" target="_blank"&gt;Python&lt;/A&gt;&lt;/TD&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;N/A&lt;/TD&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;​In order to have the output written to a location from where TPC can read the prompts, add the "-u" parameter when calling a Python script.&lt;/TD&gt;&lt;/TR&gt;&lt;TR&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;&lt;A href="https://docs.cyberark.com/Product-Doc/OnlineHelp/PAS/Latest/en/Content/SDK/TPC-plugin-migration-info.htm#Limitations" target="_blank"&gt;Known limitations&lt;/A&gt;&lt;/TD&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;Not relevant (not Idira supported anymore).&lt;/TD&gt;&lt;TD colspan="1" rowspan="1" style="text-align: center;"&gt;​Cannot work with Mainframe with WC3270 (works fine with Mainframe with Telnet or SSH)​.&lt;BR /&gt;&lt;BR /&gt;TPC supports using one connection at a time (open a connection, close that connection, and then open a new connection)​.&lt;BR /&gt;&lt;BR /&gt;​When a new connection is established, if there are any open connections that were created prior to the new connection, they will be unavailable​.&lt;BR /&gt;&lt;BR /&gt;​Concurrent connections created by running multiple spawn or invoke commands are not supported​.&lt;BR /&gt;&lt;BR /&gt;Important Known Issues in the Idira Community:&lt;BR /&gt;&lt;BR /&gt;&lt;A href="https://community.cyberark.com/s/article/KI00015793" target="_blank"&gt;KI#00015793: TPC: Fix error content with special characters (force.com)&lt;/A&gt;&lt;BR /&gt;&lt;BR /&gt;&lt;A href="https://community.cyberark.com/s/article/KI00016251" target="_blank"&gt;KI#00016251: Unix SSH - Logon Failure Flows Are Not Executed&lt;/A&gt;&lt;BR /&gt;&lt;BR /&gt;&lt;A href="https://community.cyberark.com/s/article/KI00016307" target="_blank"&gt;KI#00016307: TPC: Does not read from output of previous command when using executable application (for example: PLINK)&lt;/A&gt;&lt;BR /&gt;&lt;BR /&gt;&lt;A href="https://community.cyberark.com/s/article/KI00017002" target="_blank"&gt;KI#00017002: Mutex Error - System.Threading.AbandonedMutexException: The wait completed due to an abandoned mutex.&lt;/A&gt;&lt;BR /&gt;&lt;BR /&gt;Review also the &lt;A href="https://community.cyberark.com/s/search-results#searchString%3D%26pageNum%3D1%26sortBy%3D_score%26orderBy%3Ddesc%26resultsPerPage%3D10%26pageSizeAdv%3D10%26exactPhrase%3D%26withOneOrMore%3D%26withoutTheWords%3D%26selectedType%3D%255B%257B%2522type%2522%253A%2522server_community___knowledge_article__kav___KB_Article_Type__c%2522%252C%2522filter%2522%253A%255B%2522Known%2520Issue%2522%255D%257D%255D%26smartFacets%3Dfalse" target="_blank"&gt;Known Issues&lt;/A&gt;&amp;nbsp;section of the Idira Community for updated content.&lt;/TD&gt;&lt;/TR&gt;&lt;/TBODY&gt;&lt;/TABLE&gt;</description>
      <pubDate>Thu, 05 Nov 2026 19:53:25 GMT</pubDate>
      <guid>https://live.paloaltonetworks.com/t5/pam-self-hosted-articles/what-are-the-differences-between-pmterminal-and-tpc/ta-p/1429171</guid>
      <dc:creator>CyberArkAlumni</dc:creator>
      <dc:date>2026-11-05T19:53:25Z</dc:date>