    <description>&lt;P&gt;The documentation for upgrade of a primary-DR environment outlines a method very different from previous methods, plus is different from the "organize the upgrade" recommendation.&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Links to the pages: &lt;/P&gt;&lt;P&gt;Upgrade Preparations (section Organize the upgrade)&lt;/P&gt;&lt;P&gt;&lt;A alt="https://docs.cyberark.com/pam-self-hosted/latest/en/Content/PAS%20INST/UpgradePreparations.htm?tocpath=Installation%7CUpgrade%7C_____2#Organizetheupgrade" href="https://docs.cyberark.com/pam-self-hosted/latest/en/Content/PAS%20INST/UpgradePreparations.htm?tocpath=Installation%7CUpgrade%7C_____2#Organizetheupgrade" target="_blank"&gt;https://docs.cyberark.com/pam-self-hosted/latest/en/Content/PAS%20INST/UpgradePreparations.htm?tocpath=Installation%7CUpgrade%7C_____2#Organizetheupgrade&lt;/A&gt;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Upgrade a Primary-DR environment&lt;/P&gt;&lt;P&gt;&lt;A alt="https://docs.cyberark.com/pam-self-hosted/latest/en/Content/PAS%20INST/Upgrade-Active-Passive-Vault.htm?TocPath=Installation%7CUpgrade%7CUpgrade%20a%20Primary-DR%20Environment%7C_____0" href="https://docs.cyberark.com/pam-self-hosted/latest/en/Content/PAS%20INST/Upgrade-Active-Passive-Vault.htm?TocPath=Installation%7CUpgrade%7CUpgrade%20a%20Primary-DR%20Environment%7C_____0" target="_blank"&gt;https://docs.cyberark.com/pam-self-hosted/latest/en/Content/PAS%20INST/Upgrade-Active-Passive-Vault.htm?TocPath=Installation%7CUpgrade%7CUpgrade%20a%20Primary-DR%20Environment%7C_____0&lt;/A&gt;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Discrepancies:&lt;/P&gt;&lt;OL&gt;&lt;LI&gt;In the upgrade between major versions, it presumes there is multiple DRs, and recommends first doing the DR. (No references to if you only have one DR)&lt;/LI&gt;&lt;LI&gt; In the upgrade a Primary-DR environment it states: In general, upgrade tasks should be done in the following order; first upgrade the primary (active) Vault, and then upgrade the DR (passive) Vault. Lastly, perform the necessary post-upgrade tasks. It does not mention when you are doing all the components, although further down in the doc it shows components after post-upgrade tasks&lt;/LI&gt;&lt;LI&gt;In the workflow section, it does put the exception in regarding point 1 that it is a recommendation if you have multiple DRs. It though, then seems to indicate that with single-node, you want to do DR first. Unclear if this is someone saying "hey, this could take a long time, if you do DR first, your downtime is less"&lt;/LI&gt;&lt;LI&gt;Components are listed as pvwa, cpm , PSM, then other utilities. The order is "interesting", and differs from the "organize the upgrade" slide&lt;/LI&gt;&lt;/OL&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;We know that there isn't a one-size fits all for upgrade plans due to  the variety of customer needs, architecture, skillsets and governance requirements.&lt;/P&gt;&lt;UL&gt;&lt;LI&gt;&amp;nbsp;Outages: Some customers cannot take any outage. Others can work with a vault admin being able to get at the vault via private ark during the outage&lt;/LI&gt;&lt;LI&gt;Compliance requirements: &lt;/LI&gt;&lt;LI&gt;Architecture. Some customers have test environments that mirror, other's done. Some have clustered, high availability, other's don't. Some have only one CPM, others have low risk/low volume ones. Ditto re pvwa's, and shucks, even the ability to block users from connecting via loadbalancers and firewalls.&lt;/LI&gt;&lt;LI&gt;Resources: Some have lots of skills and depth in their teams, other's dont. &lt;/LI&gt;&lt;/UL&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Here is an example of previous upgrade plans, and a bit of the "why" re order of operations&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;UL&gt;&lt;LI&gt;One of the common old style methods was stop the vaults, upgrrade primary, then pvwa, PSM, CPM in that order.&lt;/LI&gt;&lt;LI&gt; System/unit tests done throughout and UAT occurring as sitems were brought up.&lt;/LI&gt;&lt;LI&gt; By the time CPM was done, you were committed, as the passwords were starting to rotate, and you had activities in the vault. &lt;/LI&gt;&lt;LI&gt;Finally, you would do DR. If the upgrade went south, you could live on DR until rebuilt. If primary failed while DR was being upgraded, you were in a pretty low probability scenario. Typically did not bring up DR as an alternative due to challenges of changes in DR. Just easier to take the outage in orgs that could.&lt;/LI&gt;&lt;/UL&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Now the questions/wondering: &lt;/P&gt;&lt;P&gt;If I could sit and chat with the individuals who wrote this item, I would focus my questions on two main areas: what is the backout plan, when are you doing UAT?&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Backout plan (ITIL or ITSM)&lt;/P&gt;&lt;P&gt;If DR is upgraded, you are not going to bring it up as your solution. A restore is going to be expensive. Although one would hope that you aren't going to be doing a backout, it cannot be ignored, and needs to be thought through.&lt;/P&gt;&lt;P&gt;This isn't a question of just replacing a safe or two., or a component. in a major upgrade, as noted by the backups recommended.&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Testing&lt;/P&gt;&lt;P&gt;Given CyberArks role in the org, most agencies require assurance after a major change that all governance /functionality is working as expected, including negative testing. &lt;/P&gt;&lt;P&gt;Presumption again is that if an error is found you can decide to roll-back/restore (catastrophic), remediate (minimal) or do partial restore (maybe restore component to previous version)&lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&lt;/P&gt;&lt;P&gt;As soon as the primary &amp;amp; DR are upgraded, your recovery costs increase dramatically.&lt;/P&gt;&lt;P&gt;As soon as CPM Is in, you aren't backing it out. Passwords are rotating and you are committed&lt;/P&gt;&lt;P&gt;With users in, especially if UAT only, you could still do recovery after pulling logs and knowing what creds needed to be repaired.&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;********************************&lt;/P&gt;&lt;P&gt;We did some dialogue on how people do upgrades in the Discord group. There were definitely differences of opinion, but, i feel it was rather universally, do DR last (unless you have multiple or are HA).&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;*******************&lt;/P&gt;&lt;P&gt;Questions: &lt;/P&gt;&lt;P&gt;What drove CyberArk to go to this method / upgrade path?&lt;/P&gt;&lt;P&gt;What are the recommended offsets or procedural mindshifts that are required by those who have similair concerns to mine.&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
    <pubDate>Thu, 26 Sep 2024 14:05:38 GMT</pubDate>
    <dc:creator>CyberArkAlumni</dc:creator>
    <dc:date>2024-09-26T14:05:38Z</dc:date>
    <item>
      <title>Challenge and concern related to documentation for Upgrades</title>
      <link>https://live.paloaltonetworks.com/t5/pam-self-hosted-discussions/challenge-and-concern-related-to-documentation-for-upgrades/m-p/1389808#M70523</link>
      <description>&lt;P&gt;The documentation for upgrade of a primary-DR environment outlines a method very different from previous methods, plus is different from the "organize the upgrade" recommendation.&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Links to the pages: &lt;/P&gt;&lt;P&gt;Upgrade Preparations (section Organize the upgrade)&lt;/P&gt;&lt;P&gt;&lt;A alt="https://docs.cyberark.com/pam-self-hosted/latest/en/Content/PAS%20INST/UpgradePreparations.htm?tocpath=Installation%7CUpgrade%7C_____2#Organizetheupgrade" href="https://docs.cyberark.com/pam-self-hosted/latest/en/Content/PAS%20INST/UpgradePreparations.htm?tocpath=Installation%7CUpgrade%7C_____2#Organizetheupgrade" target="_blank"&gt;https://docs.cyberark.com/pam-self-hosted/latest/en/Content/PAS%20INST/UpgradePreparations.htm?tocpath=Installation%7CUpgrade%7C_____2#Organizetheupgrade&lt;/A&gt;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Upgrade a Primary-DR environment&lt;/P&gt;&lt;P&gt;&lt;A alt="https://docs.cyberark.com/pam-self-hosted/latest/en/Content/PAS%20INST/Upgrade-Active-Passive-Vault.htm?TocPath=Installation%7CUpgrade%7CUpgrade%20a%20Primary-DR%20Environment%7C_____0" href="https://docs.cyberark.com/pam-self-hosted/latest/en/Content/PAS%20INST/Upgrade-Active-Passive-Vault.htm?TocPath=Installation%7CUpgrade%7CUpgrade%20a%20Primary-DR%20Environment%7C_____0" target="_blank"&gt;https://docs.cyberark.com/pam-self-hosted/latest/en/Content/PAS%20INST/Upgrade-Active-Passive-Vault.htm?TocPath=Installation%7CUpgrade%7CUpgrade%20a%20Primary-DR%20Environment%7C_____0&lt;/A&gt;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Discrepancies:&lt;/P&gt;&lt;OL&gt;&lt;LI&gt;In the upgrade between major versions, it presumes there is multiple DRs, and recommends first doing the DR. (No references to if you only have one DR)&lt;/LI&gt;&lt;LI&gt; In the upgrade a Primary-DR environment it states: In general, upgrade tasks should be done in the following order; first upgrade the primary (active) Vault, and then upgrade the DR (passive) Vault. Lastly, perform the necessary post-upgrade tasks. It does not mention when you are doing all the components, although further down in the doc it shows components after post-upgrade tasks&lt;/LI&gt;&lt;LI&gt;In the workflow section, it does put the exception in regarding point 1 that it is a recommendation if you have multiple DRs. It though, then seems to indicate that with single-node, you want to do DR first. Unclear if this is someone saying "hey, this could take a long time, if you do DR first, your downtime is less"&lt;/LI&gt;&lt;LI&gt;Components are listed as pvwa, cpm , PSM, then other utilities. The order is "interesting", and differs from the "organize the upgrade" slide&lt;/LI&gt;&lt;/OL&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;We know that there isn't a one-size fits all for upgrade plans due to  the variety of customer needs, architecture, skillsets and governance requirements.&lt;/P&gt;&lt;UL&gt;&lt;LI&gt;&amp;nbsp;Outages: Some customers cannot take any outage. Others can work with a vault admin being able to get at the vault via private ark during the outage&lt;/LI&gt;&lt;LI&gt;Compliance requirements: &lt;/LI&gt;&lt;LI&gt;Architecture. Some customers have test environments that mirror, other's done. Some have clustered, high availability, other's don't. Some have only one CPM, others have low risk/low volume ones. Ditto re pvwa's, and shucks, even the ability to block users from connecting via loadbalancers and firewalls.&lt;/LI&gt;&lt;LI&gt;Resources: Some have lots of skills and depth in their teams, other's dont. &lt;/LI&gt;&lt;/UL&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Here is an example of previous upgrade plans, and a bit of the "why" re order of operations&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;UL&gt;&lt;LI&gt;One of the common old style methods was stop the vaults, upgrrade primary, then pvwa, PSM, CPM in that order.&lt;/LI&gt;&lt;LI&gt; System/unit tests done throughout and UAT occurring as sitems were brought up.&lt;/LI&gt;&lt;LI&gt; By the time CPM was done, you were committed, as the passwords were starting to rotate, and you had activities in the vault. &lt;/LI&gt;&lt;LI&gt;Finally, you would do DR. If the upgrade went south, you could live on DR until rebuilt. If primary failed while DR was being upgraded, you were in a pretty low probability scenario. Typically did not bring up DR as an alternative due to challenges of changes in DR. Just easier to take the outage in orgs that could.&lt;/LI&gt;&lt;/UL&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Now the questions/wondering: &lt;/P&gt;&lt;P&gt;If I could sit and chat with the individuals who wrote this item, I would focus my questions on two main areas: what is the backout plan, when are you doing UAT?&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Backout plan (ITIL or ITSM)&lt;/P&gt;&lt;P&gt;If DR is upgraded, you are not going to bring it up as your solution. A restore is going to be expensive. Although one would hope that you aren't going to be doing a backout, it cannot be ignored, and needs to be thought through.&lt;/P&gt;&lt;P&gt;This isn't a question of just replacing a safe or two., or a component. in a major upgrade, as noted by the backups recommended.&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Testing&lt;/P&gt;&lt;P&gt;Given CyberArks role in the org, most agencies require assurance after a major change that all governance /functionality is working as expected, including negative testing. &lt;/P&gt;&lt;P&gt;Presumption again is that if an error is found you can decide to roll-back/restore (catastrophic), remediate (minimal) or do partial restore (maybe restore component to previous version)&lt;/P&gt;&lt;P&gt;&amp;nbsp;&amp;nbsp;&lt;/P&gt;&lt;P&gt;As soon as the primary &amp;amp; DR are upgraded, your recovery costs increase dramatically.&lt;/P&gt;&lt;P&gt;As soon as CPM Is in, you aren't backing it out. Passwords are rotating and you are committed&lt;/P&gt;&lt;P&gt;With users in, especially if UAT only, you could still do recovery after pulling logs and knowing what creds needed to be repaired.&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;********************************&lt;/P&gt;&lt;P&gt;We did some dialogue on how people do upgrades in the Discord group. There were definitely differences of opinion, but, i feel it was rather universally, do DR last (unless you have multiple or are HA).&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;*******************&lt;/P&gt;&lt;P&gt;Questions: &lt;/P&gt;&lt;P&gt;What drove CyberArk to go to this method / upgrade path?&lt;/P&gt;&lt;P&gt;What are the recommended offsets or procedural mindshifts that are required by those who have similair concerns to mine.&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Thu, 26 Sep 2024 14:05:38 GMT</pubDate>
      <guid>https://live.paloaltonetworks.com/t5/pam-self-hosted-discussions/challenge-and-concern-related-to-documentation-for-upgrades/m-p/1389808#M70523</guid>
      <dc:creator>CyberArkAlumni</dc:creator>
      <dc:date>2024-09-26T14:05:38Z</dc:date>
    </item>
    <item>
      <title>Re: Challenge and concern related to documentation for Upgrades</title>
      <link>https://live.paloaltonetworks.com/t5/pam-self-hosted-discussions/challenge-and-concern-related-to-documentation-for-upgrades/m-p/1389809#M70524</link>
      <description>&lt;P&gt;Hey @Jayne Little​&amp;nbsp;&lt;/P&gt;&lt;P&gt;I've sent your questions to our Docs team to see if someone can provide a response here. &lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;-Matt&lt;/P&gt;</description>
      <pubDate>Thu, 26 Sep 2024 14:43:42 GMT</pubDate>
      <guid>https://live.paloaltonetworks.com/t5/pam-self-hosted-discussions/challenge-and-concern-related-to-documentation-for-upgrades/m-p/1389809#M70524</guid>
      <dc:creator>CyberArkAlumni</dc:creator>
      <dc:date>2024-09-26T14:43:42Z</dc:date>
    </item>
    <item>
      <title>Re: Challenge and concern related to documentation for Upgrades</title>
      <link>https://live.paloaltonetworks.com/t5/pam-self-hosted-discussions/challenge-and-concern-related-to-documentation-for-upgrades/m-p/1389810#M70525</link>
      <description>&lt;P&gt;ps, I am curious about this message as well "If the upgrade process fails on the&amp;nbsp;DR Vault, the server cannot be reverted back to its original state. If this happens, contact CyberArk Support."&lt;/P&gt;&lt;P&gt;I can imagine the response of a change management on a request for change that said , "if the upgrade fails, we're calling cyberArk" with no implications or expectations/&lt;/P&gt;&lt;P&gt;This seems like a tech writer was writing this up, and asked someone, "what happens if it goes wrong" and they said "they call support"&lt;/P&gt;</description>
      <pubDate>Thu, 26 Sep 2024 19:11:25 GMT</pubDate>
      <guid>https://live.paloaltonetworks.com/t5/pam-self-hosted-discussions/challenge-and-concern-related-to-documentation-for-upgrades/m-p/1389810#M70525</guid>
      <dc:creator>CyberArkAlumni</dc:creator>
      <dc:date>2024-09-26T19:11:25Z</dc:date>
    </item>
    <item>
      <title>Re: Challenge and concern related to documentation for Upgrades</title>
      <link>https://live.paloaltonetworks.com/t5/pam-self-hosted-discussions/challenge-and-concern-related-to-documentation-for-upgrades/m-p/1389811#M70526</link>
      <description>&lt;P&gt;Thank-you&lt;/P&gt;</description>
      <pubDate>Fri, 27 Sep 2024 12:58:26 GMT</pubDate>
      <guid>https://live.paloaltonetworks.com/t5/pam-self-hosted-discussions/challenge-and-concern-related-to-documentation-for-upgrades/m-p/1389811#M70526</guid>
      <dc:creator>CyberArkAlumni</dc:creator>
      <dc:date>2024-09-27T12:58:26Z</dc:date>
    </item>
    <item>
      <title>Re: Challenge and concern related to documentation for Upgrades</title>
      <link>https://live.paloaltonetworks.com/t5/pam-self-hosted-discussions/challenge-and-concern-related-to-documentation-for-upgrades/m-p/1389812#M70527</link>
      <description>&lt;P&gt;This is a great question since Support is not setup to handle/assist with upgrades or upgrade failures outside of getting the customer back into a usable state - which is usually rolling back to their previous version. &lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;To fix something like this/roll back: From my experience the process would be to wipe the machine and install a clean OS along with a fresh Vault installation. &lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;-Matt&lt;/P&gt;</description>
      <pubDate>Fri, 27 Sep 2024 16:32:35 GMT</pubDate>
      <guid>https://live.paloaltonetworks.com/t5/pam-self-hosted-discussions/challenge-and-concern-related-to-documentation-for-upgrades/m-p/1389812#M70527</guid>
      <dc:creator>CyberArkAlumni</dc:creator>
      <dc:date>2024-09-27T16:32:35Z</dc:date>
    </item>
    <item>
      <title>Re: Challenge and concern related to documentation for Upgrades</title>
      <link>https://live.paloaltonetworks.com/t5/pam-self-hosted-discussions/challenge-and-concern-related-to-documentation-for-upgrades/m-p/1389813#M70528</link>
      <description>&lt;P&gt;M - yes; hence the concerns re the current documentation re upgrade activities.&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;With new features, CyberArk is ever evolving the capabilities and providing newer &amp;amp; more efficient methodologies.&lt;/P&gt;&lt;P&gt;We know that individuals  read the upgrade documentation and say "CyberArk says to do it this way"&lt;/P&gt;&lt;P&gt;Sometimes we can read them, and say "aaah, interesting, that makes sense."  Challenges are encountered when those documents or new methods  are inconsistent within the documentation set and even more importantly, do not address risk mitigation which previous methods implemented.   We burn hours for the customer, the partner, and our own time..&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Fri, 27 Sep 2024 16:41:48 GMT</pubDate>
      <guid>https://live.paloaltonetworks.com/t5/pam-self-hosted-discussions/challenge-and-concern-related-to-documentation-for-upgrades/m-p/1389813#M70528</guid>
      <dc:creator>CyberArkAlumni</dc:creator>
      <dc:date>2024-09-27T16:41:48Z</dc:date>
    </item>
    <item>
      <title>Re: Challenge and concern related to documentation for Upgrades</title>
      <link>https://live.paloaltonetworks.com/t5/pam-self-hosted-discussions/challenge-and-concern-related-to-documentation-for-upgrades/m-p/1389814#M70529</link>
      <description>&lt;P&gt;In most of my change controls, I've actually said escalating to cyberark for assistance is part of the back out plans. Have never been challenged really. &lt;/P&gt;</description>
      <pubDate>Mon, 30 Sep 2024 02:28:45 GMT</pubDate>
      <guid>https://live.paloaltonetworks.com/t5/pam-self-hosted-discussions/challenge-and-concern-related-to-documentation-for-upgrades/m-p/1389814#M70529</guid>
      <dc:creator>Mal</dc:creator>
      <dc:date>2024-09-30T02:28:45Z</dc:date>
    </item>
    <item>
      <title>Re: Challenge and concern related to documentation for Upgrades</title>
      <link>https://live.paloaltonetworks.com/t5/pam-self-hosted-discussions/challenge-and-concern-related-to-documentation-for-upgrades/m-p/1389815#M70530</link>
      <description>&lt;P&gt;Thanks @Jayne Little​&amp;nbsp;for sharing your thoughts. I do have one more point to add here @Matt Jennison​&amp;nbsp;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Each upgrade brings certain security enhancements, and after the upgrade we perform the hardening again. However, its not clear that what exact changes that version upgrade brings to the system and what modifications are going to be changed at OS layer.&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;It would be great to include security changes being made with each upgrade and to help analyzing beforehand how each parameter is going to impact the environment.  &lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Mon, 30 Sep 2024 02:31:10 GMT</pubDate>
      <guid>https://live.paloaltonetworks.com/t5/pam-self-hosted-discussions/challenge-and-concern-related-to-documentation-for-upgrades/m-p/1389815#M70530</guid>
      <dc:creator>M.Vora780263</dc:creator>
      <dc:date>2024-09-30T02:31:10Z</dc:date>
    </item>
    <item>
      <title>Re: Challenge and concern related to documentation for Upgrades</title>
      <link>https://live.paloaltonetworks.com/t5/pam-self-hosted-discussions/challenge-and-concern-related-to-documentation-for-upgrades/m-p/1389816#M70531</link>
      <description>&lt;P&gt;Thanks @Malhar Vora​&amp;nbsp;!&lt;/P&gt;&lt;P&gt;I'm still working to get our docs team to reply here, but I am providing them this feedback!&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;-Matt&lt;/P&gt;</description>
      <pubDate>Mon, 30 Sep 2024 13:27:47 GMT</pubDate>
      <guid>https://live.paloaltonetworks.com/t5/pam-self-hosted-discussions/challenge-and-concern-related-to-documentation-for-upgrades/m-p/1389816#M70531</guid>
      <dc:creator>CyberArkAlumni</dc:creator>
      <dc:date>2024-09-30T13:27:47Z</dc:date>
    </item>
    <item>
      <title>Re: Challenge and concern related to documentation for Upgrades</title>
      <link>https://live.paloaltonetworks.com/t5/pam-self-hosted-discussions/challenge-and-concern-related-to-documentation-for-upgrades/m-p/1389817#M70532</link>
      <description>&lt;P&gt;Hi Jayne, &lt;/P&gt;&lt;P&gt;As you know DR with CyberArk vaults is always interesting as its both a process of replication and a vault that would sit in a DR environment. &lt;/P&gt;&lt;P&gt;Downtime is a luxury so having extra on prem vaults that run the DR process in a production datacentre are essential to having a recovery option that doesn't involve instigating the use of the DR datacentre. So doing DR first and failing to it (taken literally isn't an option) As for self-hosted cloud this would translate to roles of Vault, DR and DR (if you elect for the 3rd vault) does open the option to upgrade DR first and fail over to it as one of them would be for high availability and the other for DR, that way you still have a DR to fall back to if needed. I can’t imagine not having something to fail over to or fall back to in the event that something has gone wrong with the upgrade.&lt;/P&gt;&lt;P&gt;Its always good to follow vendor guidelines but as ever it need to be translated to the operating environment.&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Tue, 01 Oct 2024 17:48:43 GMT</pubDate>
      <guid>https://live.paloaltonetworks.com/t5/pam-self-hosted-discussions/challenge-and-concern-related-to-documentation-for-upgrades/m-p/1389817#M70532</guid>
      <dc:creator>CyberArkAlumni</dc:creator>
      <dc:date>2024-10-01T17:48:43Z</dc:date>
    </item>
    <item>
      <title>Re: Challenge and concern related to documentation for Upgrades</title>
      <link>https://live.paloaltonetworks.com/t5/pam-self-hosted-discussions/challenge-and-concern-related-to-documentation-for-upgrades/m-p/1389818#M70533</link>
      <description>&lt;P&gt;Any update?  &lt;/P&gt;</description>
      <pubDate>Tue, 08 Oct 2024 17:26:47 GMT</pubDate>
      <guid>https://live.paloaltonetworks.com/t5/pam-self-hosted-discussions/challenge-and-concern-related-to-documentation-for-upgrades/m-p/1389818#M70533</guid>
      <dc:creator>CyberArkAlumni</dc:creator>
      <dc:date>2024-10-08T17:26:47Z</dc:date>
    </item>
    <item>
      <title>Re: Challenge and concern related to documentation for Upgrades</title>
      <link>https://live.paloaltonetworks.com/t5/pam-self-hosted-discussions/challenge-and-concern-related-to-documentation-for-upgrades/m-p/1389819#M70534</link>
      <description>&lt;P&gt;I'm still actively requesting someone respond every few days. I'm sorry it's taking a bit of time!&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;-Matt&lt;/P&gt;</description>
      <pubDate>Tue, 08 Oct 2024 17:36:54 GMT</pubDate>
      <guid>https://live.paloaltonetworks.com/t5/pam-self-hosted-discussions/challenge-and-concern-related-to-documentation-for-upgrades/m-p/1389819#M70534</guid>
      <dc:creator>CyberArkAlumni</dc:creator>
      <dc:date>2024-10-08T17:36:54Z</dc:date>
    </item>
    <item>
      <title>Re: Challenge and concern related to documentation for Upgrades</title>
      <link>https://live.paloaltonetworks.com/t5/pam-self-hosted-discussions/challenge-and-concern-related-to-documentation-for-upgrades/m-p/1389820#M70535</link>
      <description>&lt;P&gt;Hi Jayne,&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;I am writing from the documentation team. This is the answer we received from R&amp;amp;D:&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;In version 14.0, we added a new feature that enables customers to remove the full replication step ( DR/Satellite) after the upgrade.&lt;/P&gt;&lt;P&gt;This significantly reduces the upgrade time and increases the availability of DR. &lt;/P&gt;&lt;P&gt;The condition to ‘earn’ this feature is to upgrade the Primary first and then the DR.&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Customers can work with the old procedure, but full replication will be required for each DR.&lt;/P&gt;</description>
      <pubDate>Mon, 21 Oct 2024 07:23:23 GMT</pubDate>
      <guid>https://live.paloaltonetworks.com/t5/pam-self-hosted-discussions/challenge-and-concern-related-to-documentation-for-upgrades/m-p/1389820#M70535</guid>
      <dc:creator>CyberArkAlumni</dc:creator>
      <dc:date>2024-10-21T07:23:23Z</dc:date>
    </item>
    <item>
      <title>Re: Challenge and concern related to documentation for Upgrades</title>
      <link>https://live.paloaltonetworks.com/t5/pam-self-hosted-discussions/challenge-and-concern-related-to-documentation-for-upgrades/m-p/1389821#M70536</link>
      <description>&lt;P&gt;I presume you are referring to background feature?&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;What the response doesn't do is answer the questions&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;what is the backout plan, when are you doing UAT?&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Wed, 23 Oct 2024 01:17:02 GMT</pubDate>
      <guid>https://live.paloaltonetworks.com/t5/pam-self-hosted-discussions/challenge-and-concern-related-to-documentation-for-upgrades/m-p/1389821#M70536</guid>
      <dc:creator>CyberArkAlumni</dc:creator>
      <dc:date>2024-10-23T01:17:02Z</dc:date>
    </item>
    <item>
      <title>Re: Challenge and concern related to documentation for Upgrades</title>
      <link>https://live.paloaltonetworks.com/t5/pam-self-hosted-discussions/challenge-and-concern-related-to-documentation-for-upgrades/m-p/1389822#M70537</link>
      <description>&lt;P&gt;hey @Jayne Little​&amp;nbsp;&lt;/P&gt;&lt;P&gt;I'm still working on getting an answer from PM on this. I'm very sorry for the delay. &lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;-Matt&lt;/P&gt;</description>
      <pubDate>Wed, 06 Nov 2024 15:49:40 GMT</pubDate>
      <guid>https://live.paloaltonetworks.com/t5/pam-self-hosted-discussions/challenge-and-concern-related-to-documentation-for-upgrades/m-p/1389822#M70537</guid>
      <dc:creator>CyberArkAlumni</dc:creator>
      <dc:date>2024-11-06T15:49:40Z</dc:date>
    </item>
    <item>
      <title>Re: Challenge and concern related to documentation for Upgrades</title>
      <link>https://live.paloaltonetworks.com/t5/pam-self-hosted-discussions/challenge-and-concern-related-to-documentation-for-upgrades/m-p/1389823#M70538</link>
      <description>&lt;P&gt;&lt;B&gt;DV response inline &lt;/B&gt;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Discrepancies:&lt;/P&gt;&lt;OL&gt;&lt;LI&gt;In the upgrade between major versions, it presumes there is multiple DRs, and recommends first doing the DR. (No references to if you only have one DR)&lt;/LI&gt;&lt;/OL&gt;&lt;P&gt;This is correct: the purpose here is to validate major changes during the upgrade process on the DR and after running it on the Primary Vault – It is not relevant if you have many DRs the purpose is to valid it&amp;nbsp;only on one DR &lt;/P&gt;&lt;P&gt;While the Primary continues working. &lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;OL&gt;&lt;LI&gt;The upgrade a Primary-DR environment states: In general, upgrade tasks should be done in the following order; first upgrade the primary (active) Vault, and then upgrade the DR (passive) Vault. Lastly, perform the necessary post-upgrade tasks. It does not mention when you are doing all the components, although further down in the doc it shows components after post-upgrade tasks&lt;/LI&gt;&lt;/OL&gt;&lt;P&gt;&lt;B&gt;&lt;I&gt;The ‘organize the upgrade’ page is a general page at a high level for all PAM environments, and the future down pages we describe the upgrade flow for each component. &lt;/I&gt;&lt;/B&gt;&lt;/P&gt;&lt;P&gt;&lt;B&gt;&lt;I&gt;Under the Vault components, we don't mention the other component flow and refer only to Vault utilities under the Vault area.&lt;/I&gt;&amp;nbsp;&lt;/B&gt;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;OL&gt;&lt;LI&gt;In the workflow section, it does put the exception in regarding point 1 that it is a recommendation if you have multiple DRs. It though, then seems to indicate that with single-node, you want to do DR first. Unclear if this is someone saying "hey, this could take a long time, if you do DR first, your downtime is less"&lt;/LI&gt;&lt;/OL&gt;&lt;P&gt;&lt;B&gt;&lt;I&gt;No, the purpose here is as mentioned above: “validate the upgrade process for your environment before you upgrade your&amp;nbsp;Primary Vault.”&lt;/I&gt;&lt;/B&gt;&lt;/P&gt;&lt;P&gt;&lt;B&gt;&lt;I&gt;To reduce upgrade time /downtime, you need to upgrade first the primary and later the DR, and this will reduce the full replication step you need to run after the DR upgrade (only from V14.0) &lt;/I&gt;&lt;/B&gt;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;OL&gt;&lt;LI&gt;Components are listed as pvwa, cpm , PSM, then other utilities. The order is "interesting", and differs from the "organize the upgrade" slide&lt;/LI&gt;&lt;/OL&gt;&lt;P&gt;&lt;B&gt;&lt;I&gt;The upgrade order for PVWA, CPM, and PSM should be approved by EPV/PSM.&lt;/I&gt;&lt;/B&gt;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Now the questions/wondering: &lt;/P&gt;&lt;P&gt;One common old style method was to stop the vaults, upgrrade primary, then pvwa, PSM, and CPM in that order. System/unit tests done throughout and UAT occurring as sitems were brought up. By the time CPM was done, you were committed, as the passwords were starting to rotate, and you had activities in the vault. Then, you would do DR. If the upgrade went south, you could live on DR until rebuilt. If primary failed while DR was being upgraded, you were in a pretty low probability scenario. &lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&lt;B&gt;&lt;I&gt;We're not familiar with such procedure&amp;nbsp;we recommend and test the procedure in docs:  stop the CPM&lt;/I&gt;&lt;/B&gt; &lt;A alt="https://docs.cyberark.com/pam-self-hosted/latest/en/content/pas%20inst/upgradepreparations.htm?tocpath=Installer%7CUpgrade%7C_____2#:~:text=%3E%20Upgrade%20%3E-,Upgrade%20preparations,-Get%20Started" href="https://docs.cyberark.com/pam-self-hosted/latest/en/content/pas%20inst/upgradepreparations.htm?tocpath=Installer%7CUpgrade%7C_____2#:~:text=%3E%20Upgrade%20%3E-,Upgrade%20preparations,-Get%20Started" target="_blank"&gt;https://docs.cyberark.com/pam-self-hosted/latest/en/content/pas%20inst/upgradepreparations.htm?tocpath=Installer%7CUpgrade%7C_____2#:~:text=%3E%20Upgrade%20%3E-,Upgrade%20preparations,-Get%20Started&lt;/A&gt; &lt;/P&gt;&lt;P&gt;&lt;B&gt;then upgrade the Primary-&amp;gt; upgrade the DR and run the test against Primarily using the PrivateArk client&lt;/B&gt;&lt;/P&gt;&lt;P&gt;&lt;B&gt;and last upgrade the Vault’s utilities&lt;/B&gt; &lt;A alt="https://docs.cyberark.com/pam-self-hosted/latest/en/content/pas%20inst/upgrading-the-cyberark-vault-server.htm?tocpath=Installer%7CUpgrade%7CUpgrade%20a%20Primary-DR%20Environment%7C_____2#AfterupgradingaVault" href="https://docs.cyberark.com/pam-self-hosted/latest/en/content/pas%20inst/upgrading-the-cyberark-vault-server.htm?tocpath=Installer%7CUpgrade%7CUpgrade%20a%20Primary-DR%20Environment%7C_____2#AfterupgradingaVault" target="_blank"&gt;https://docs.cyberark.com/pam-self-hosted/latest/en/content/pas%20inst/upgrading-the-cyberark-vault-server.htm?tocpath=Installer%7CUpgrade%7CUpgrade%20a%20Primary-DR%20Environment%7C_____2#AfterupgradingaVault&lt;/A&gt;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;If I could sit and chat with the individuals who wrote this item, I would focus my questions on two main areas: what is the backout plan, when are you doing UAT?&lt;/P&gt;&lt;P&gt;Backout plan (ITIL or ITSM)&lt;/P&gt;&lt;P&gt;If DR is upgraded, you are not going to bring it up as your solution. A restore is going to be expensive. Although one would hope that you aren't going to be doing a backout, it cannot be ignored, and needs to be thought through.&lt;/P&gt;&lt;P&gt;You haven't done UAT as the CPM, PVWA, etc are done way after&lt;/P&gt;&lt;P&gt;&lt;B&gt;In case you choose first to validate the upgrade on the DR, you need to upgrade this DR as primary, run the tests using Private Ark Client, and after connect this Vault back to the environment and change his role to DR with full replication. &lt;/B&gt;&lt;/P&gt;&lt;P&gt;&lt;B&gt;As you mentioned, the backup plan for this DR is to restore it; there is no other solution for that.&amp;nbsp;&lt;/B&gt;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Thank you&lt;B&gt;.&lt;/B&gt;&lt;/P&gt;&lt;P&gt;Galit &lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Tue, 12 Nov 2024 08:17:14 GMT</pubDate>
      <guid>https://live.paloaltonetworks.com/t5/pam-self-hosted-discussions/challenge-and-concern-related-to-documentation-for-upgrades/m-p/1389823#M70538</guid>
      <dc:creator>CyberArkAlumni</dc:creator>
      <dc:date>2024-11-12T08:17:14Z</dc:date>
    </item>
    <item>
      <title>Re: Challenge and concern related to documentation for Upgrades</title>
      <link>https://live.paloaltonetworks.com/t5/pam-self-hosted-discussions/challenge-and-concern-related-to-documentation-for-upgrades/m-p/1389824#M70539</link>
      <description>&lt;P&gt;Galit, Private Ark client does not allow for much testing at all.   It is a bare bones, basically it confirms you can connect.&lt;/P&gt;&lt;P&gt;To do UAT (User Acceptance Testing) one must have the PVWA and ideally the ability to run reports.  Private Ark is a  unit test at best, possibly could be considered part of UAT for vault admins, but, not for the system.&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;The background replication is great new feature, especially for those with multiple DRs.  No questions there.&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;I'm struggling understanding some of your responses.&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Overall, though, what I am still not understanding is the recommended backout plan if you have upgraded both primary &amp;amp; DR and then realize you can't continue.&lt;/P&gt;&lt;P&gt;My current understanding is that you are  doing a bare metal restore onto a server:  Laying down the previous version's software, then doing a restore from backups of the safes.&lt;/P&gt;&lt;P&gt;Why:  the vault appliance doesn't have a full backup of itself and the vault.  &lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;If you upgrade DR, and leave the primary up, changes are being made from PVWA, CPM &amp;amp; PSM whilst the DR is upgraded.  &lt;/P&gt;&lt;P&gt;To do UAT, you need PVWA  (then PSM).   CPM never runs against a DR environment, unless you are going to be down for a while.&lt;/P&gt;&lt;P&gt;While you have PVWA up and PSM up, users can, unless they are blocked by solid firewall rules get in, and accounts can be used, passwords changed manually, recordings be made.&lt;/P&gt;&lt;P&gt;You need to get these back to the primary, after it is upgraded.&lt;/P&gt;&lt;P&gt;The challenge is, you have had the primary up while you are doing DR, and you also have had DR up while you were doing primary...and you haven't done replication at all yet.&lt;/P&gt;&lt;P&gt;Why?  You can't replicate from 14.2 to 12.x.  (upgraded DR to existing primary)&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&lt;B&gt;&lt;I&gt;The upgrade order for PVWA, CPM, and PSM should be approved by EPV/PSM.&lt;/I&gt;&lt;/B&gt;&lt;/P&gt;&lt;P&gt;&lt;I&gt;What do you mean by the above?  Is there a group called EPV/PSM?  or are you asking someone in the document group to review the order of components with the enterprise password vaults, product solutions manager?&lt;/I&gt;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Tue, 12 Nov 2024 14:21:55 GMT</pubDate>
      <guid>https://live.paloaltonetworks.com/t5/pam-self-hosted-discussions/challenge-and-concern-related-to-documentation-for-upgrades/m-p/1389824#M70539</guid>
      <dc:creator>CyberArkAlumni</dc:creator>
      <dc:date>2024-11-12T14:21:55Z</dc:date>
    </item>
    <item>
      <title>Re: Challenge and concern related to documentation for Upgrades</title>
      <link>https://live.paloaltonetworks.com/t5/pam-self-hosted-discussions/challenge-and-concern-related-to-documentation-for-upgrades/m-p/1389825#M70540</link>
      <description>&lt;P&gt;Why: the vault appliance doesn't have a full backup of itself and the Vault&lt;/P&gt;&lt;P&gt;The Vault has the DR for backup and the Replicate utility for backup and restore - I'm not sure which other option you mean.&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;You are correct. If you choose to upgrade the DR before the Primary, you need to run a full backup to complete all gaps and password changes when you connect this DR back to the Primary (only after the Primary upgrade -as explained in the 'upgrade between major versions' page).&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt; For testing the DR upgrade, you need to start the PrivateArk service (making the DR Primary only for testing) so you will be able to connect the clients you mentioned. &lt;/P&gt;&lt;P&gt; &lt;/P&gt;&lt;P&gt;For example: You have Primary + 2 DR version 12.6&lt;/P&gt;&lt;OL&gt;&lt;LI&gt;Primary + DR 1  continues working and provides full service&lt;/LI&gt;&lt;LI&gt;Stop DR 2 &lt;OL&gt;&lt;LI&gt;Upgrade Vault on DR2&lt;/LI&gt;&lt;LI&gt;Upgrade DR&lt;/LI&gt;&lt;LI&gt;Start the Vault&amp;nbsp;machine as a standalone&amp;nbsp;Primary Vault,&amp;nbsp;and you can then verify that&amp;nbsp;the Vault&amp;nbsp;is operating correctly with the clients.&lt;/LI&gt;&lt;/OL&gt;&lt;/LI&gt;&lt;/OL&gt;&lt;P&gt;after Validate the upgrade, now you can continue with the upgrade:&lt;/P&gt;&lt;OL&gt;&lt;LI&gt;Upgrade Primary&lt;/LI&gt;&lt;LI&gt;Upgrade DR1 - no need to run full backup (v14.0 and up)&lt;/LI&gt;&lt;LI&gt;Upgrade DR2 with full backup&lt;/LI&gt;&lt;/OL&gt;&lt;P&gt;I skipped some steps the full procedure is here &lt;/P&gt;&lt;P&gt;https://docs.cyberark.com/pam-self-hosted/latest/en/content/pas%20inst/upgrading-the-cyberark-vault-server-passive-between-versions.htm?tocpath=Installer%7CUpgrade%7CUpgrade%20a%20Primary-DR%20Environment%7C_____1&lt;/P&gt;&lt;P&gt; &lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;You can't replicate from 14.2 to 12. x because the database structure is different between versions. Before you replicate the data, you need to have an identical database structure—this is how replication works.&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&lt;B&gt;&lt;I&gt;The upgrade order for PVWA, CPM, and PSM should be approved by EPV/PSM.&lt;/I&gt;&lt;/B&gt;&lt;/P&gt;&lt;P&gt;Yes, these are different groups. The documentation provides separate guidelines for upgrading those components. &lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Tue, 12 Nov 2024 17:20:00 GMT</pubDate>
      <guid>https://live.paloaltonetworks.com/t5/pam-self-hosted-discussions/challenge-and-concern-related-to-documentation-for-upgrades/m-p/1389825#M70540</guid>
      <dc:creator>CyberArkAlumni</dc:creator>
      <dc:date>2024-11-12T17:20:00Z</dc:date>
    </item>
    <item>
      <title>Re: Challenge and concern related to documentation for Upgrades</title>
      <link>https://live.paloaltonetworks.com/t5/pam-self-hosted-discussions/challenge-and-concern-related-to-documentation-for-upgrades/m-p/1389826#M70541</link>
      <description>&lt;P&gt;Me: Why: the vault appliance doesn't have a full backup of itself and the Vault&lt;/P&gt;&lt;P&gt;&lt;I&gt;Galit: The Vault has the DR for backup and the Replicate utility for backup and restore - I'm not sure which other option you mean.&lt;/I&gt;&lt;/P&gt;&lt;P&gt;Me: If I were to take a snapshot of a component server, I would have a snapshot that had the contents of all the folders, as well as the db, including registry settings&lt;/P&gt;&lt;P&gt; If we consider the full appliance, to my knowledge, we cannot restore the appliance. Is there a utility that would back up the vaults registry settings, folders (non-CyberArk) that I am forgetting about?&lt;/P&gt;&lt;P&gt; Reason: upgrades typically impact more than the db.&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;I feel that you are likely speaking to the technical activities, rather than typical change management / ITIL requirements. These include the requirement to be able to back out the change.&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;split brain potential&lt;/P&gt;&lt;P&gt;Reason: The Primary is working and presenting to users -- accounts are being accessed, records are being written, passwords are being changed. (The risk can be reduced if PSM/CPm are both down; however, there will be activity in an environment if available to users and/or services such as CPM.)&lt;/P&gt;&lt;P&gt;If you bring up the DR vault and point components to it for testing, you now have both environments up &amp;amp; servicing users. At this point, you have the potential for split-brain.&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&lt;I&gt;you: You can't replicate from 14.2 to 12. x because the database structure is different between versions. Before you replicate the data, you need to have an identical database structure—this is how replication works.&lt;/I&gt;&lt;/P&gt;&lt;P&gt;Yes, i understand how replication works. My point was that if you decide to not proceed with the upgrade due to issues encountered during testing, you have made changes in the DR vault that must make it back to the primary vault. You can't make that happen if the primary is still on 12.x&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;In your scenario, you have two DRs.&lt;/P&gt;&lt;P&gt;Is a prerequisite for the methodology that you are presenting that two DR's be present? In situations where there is only 1 DR, you don't have a DR available once you start the upgrade. This may be an acceptable risk.&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&amp;nbsp;Thank-you for confirming it is a separate group that would provide feedback re components.&lt;/P&gt;&lt;P&gt;Yet, I feel, you can't answer one without considering the other.&lt;/P&gt;&lt;P&gt;It is a CyberArk environment  that is being upgraded.  Not just the vault, not just the components.  &lt;/P&gt;&lt;P&gt;As people who are tasked with doing upgrade testing, evidence for control groups, there are well orchestrated tests that must be executed.    &lt;/P&gt;&lt;P&gt;It is the full suite that is validated.  Not just one piece.  It's like saying  a new car is working well, as the engine is working, when the tires aren't on the car.&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Tue, 12 Nov 2024 18:27:21 GMT</pubDate>
      <guid>https://live.paloaltonetworks.com/t5/pam-self-hosted-discussions/challenge-and-concern-related-to-documentation-for-upgrades/m-p/1389826#M70541</guid>
      <dc:creator>CyberArkAlumni</dc:creator>
      <dc:date>2024-11-12T18:27:21Z</dc:date>