Hello all

I'm new in HSM configuration

I configured the   setup hardware security module. with a PANOS version 7 

the result was success  

and in the admin guide is wrote that you have to configured the Setup HSM Partition

but this does exist in the Hardware Security Operations area.

 

any idee

HSM.png

Tags (1)
Highlighted
L4 Transporter

Re: HSM setup in PAN-OS 7 setup HSM partition missing

a source nat was implementing between the palo and the hsm

and there is a verification of the palo ip with ntls ipcheck fonction enable by default

 

LUNA doc

 

and to resolve just disable it with this command on the luna HSM

ntls ipcheck disable 

 

 