OSPF BPA PARAMETERS

cancel
Showing results for 
Show  only  | Search instead for 
Did you mean: 
Announcements
Please sign in to see details of an important advisory in our Customer Advisories area.

OSPF BPA PARAMETERS

L1 Bithead

Hi Everyone,

 

We r using OSPF over IPsec tunnel.We have two tunnels and failover dynamiclly.But when we r shutdown one tunnel there r many pinng loss(10 ping loss).We want to minimnize this value.Did any one do that before? Which value we should use for this config?

2 REPLIES 2

L3 Networker

There are two pieces in this question. I believe that you are asking related to 2) because you manually shut down the tunnel.

 

1) Tunnel monitor (reducing the tunnel failover time)
Reduce the Monitor profile 'Interval' and 'Threshold' on the Network -> Network Profiles -> Monitor.
2) OSPF timing (reducing the convergence time)
Reduce the Hello Interval (sec) - by changing the 'Hello Interval' (default: 10 seconds) on the Network -> Virtual Routers -> OSPF.

 

Hope this helps,

 

--
"The Simplicity is the ultimate sophistication." - Leonardo da Vinci.

L2 Linker

Hello 

Did you get an answer to your question. If you are still experiencing packet loss during tunnel failover, please open a support ticket.

A review of the details will be helpful in answering your question.

 

Kavi

  • 2547 Views
  • 2 replies
  • 0 Likes
Like what you see?

Show your appreciation!

Click Like if a post is helpful to you or if you just want to show your support.

Click Accept as Solution to acknowledge that the answer to your question has been provided.

The button appears next to the replies on topics you’ve started. The member who gave the solution and all future visitors to this topic will appreciate it!

These simple actions take just seconds of your time, but go a long way in showing appreciation for community members and the LIVEcommunity as a whole!

The LIVEcommunity thanks you for your participation!