Yes...PA TAC assisted us in resolving the issue. Below is the case notes.

 

> less mp-log useridd.log

 

Looking at User-ID logs, there were repeated logs:
2019-04-23 12:36:36.704 +1000 Error: pan_user_id_win_log_query(pan_user_id_win.c:1364): log query for sydcwdc01.mainstreambpo.local failed: NTSTATUS: NT code 0x80041003 - NT code 0x80041003
2019-04-23 12:36:36.704 +1000 Error: pan_user_id_win_get_error_status(pan_user_id_win.c:1055): WMIC message from server sydcwdc01.mainstreambpo.local: NTSTATUS: NT code 0x80041003 - NT code 0x80041003

WMI error code 0x80041003 indicates the account does not have permission.
https://docs.microsoft.com/en-gb/windows/desktop/WmiSdk/wmi-error-constants

Please check that the service account (mainstreambpo\palocw) is member of Event Log Readers and Distributed COM Users

Some useful commands related to User-ID:
- Restart User-ID service: debug software restart process user-id
- View server monitor statistics: show user server-monitor statistics

 

Other than the group membership of service account, kindly also check the WMI permission in every DC server being used under Server Monitoring. This WMI permission is local configuration (not replicated).

Agentless User-ID 'Access Denied' Error In Server Monitor
https://knowledgebase.paloaltonetworks.com/KCSArticleDetail?id=kA10g000000Clk0CAC

 

We checked that we have given all the correct permissions on the WMI side for all our DCs. 
We asked for a trace to run to figure out what exactly its failing on when it accesses the AD side of things.

 

PA TAC provided us the following.

 

Provided that the WMI permissions are set, can you test to do WMI remote connection using wbemtest?
1. In any windows client (domain member), run wbemtest
2. Default namespace is 'root\cimv2', please change to '\\<dcservername>\root\cimv2'
3. Provide username and password (firewall service account), then click Connect
4. Observe if there is error message when wbemtest is trying to connect to DC server

Link: https://blogs.technet.microsoft.com/configmgrdogs/2014/08/20/test-your-collection-wql-queries-using-...

 

This fixed the issue!