My backup PA-3420 in an HA peer will not detect SFPs or link on any port (including copper) but the management. The primary unit detects and links on multiple SFP slots with multiple different SFP types and brands. The same SFPs in the backup unit will not detect.
adrian.admin@PA_CorpEdge_A(active)> show system state | match sys.s1.p13.capability\|sys.s1.p13.phy
sys.s1.p13.capability: [ auto, 1Gb/s-full, 10Gb/s-full, ]
sys.s1.p13.phy: { 'duration': 3600, 'last-sample': 2024-01-08 15:24:27, 'link-partner': { }, 'media': SFP-Plus-Fiber, 'sfp': { 'ch1': { 'rx-power': 0.00 mW, 'tx-bias': 5.82 mA, 'tx-power': 0.60 mW, }, 'connector': LC, 'diagnostic-monitor': Yes, 'encoding': Reserved, 'ex-spec-compliance-code': 0x0, 'identifier': SFP, 'link-len-km': 0 km, 'link-len-m': 0 m, 'link-len-om1': 30 m, 'link-len-om2': 80 m, 'link-len-om3': 300 m, 'link-len-om4': 0 m, 'rx-power-alarm-hi': 2.00 mW, 'rx-power-alarm-lo': 0.03 mW, 'rx-power-warn-hi': 0.79 mW, 'rx-power-warn-lo': 0.03 mW, 'supply-voltage': 3.32 V, 'temp-alarm-hi': 85.00 C, 'temp-alarm-lo': -5.00 C, 'temp-warn-hi': 80.00 C, 'temp-warn-lo': 0.00 C, 'temperature': 26.48 C, 'transceiver': 10000B-SR, 'tx-bias-alarm-hi': 10.50 mA, 'tx-bias-alarm-lo': 2.50 mA, 'tx-bias-warn-hi': 10.50 mA, 'tx-bias-warn-lo': 2.50 mA, 'tx-power-alarm-hi': 2.00 mW, 'tx-power-alarm-lo': 0.13 mW, 'tx-power-warn-hi': 0.79 mW, 'tx-power-warn-lo': 0.32 mW, 'vendor-name': AVAGO , 'vendor-part-number': AFBR-709SMZ-NA1 , 'vendor-part-rev': G4.1, 'vendor-serial-number': AA1723300NG , 'voltage-alarm-hi': 3.60 V, 'voltage-alarm-lo': 3.00 V, 'voltage-warn-hi': 3.46 V, 'voltage-warn-lo': 3.13 V, }, 'type': Ethernet, }
peer.sys.s1.p13.capability: [ auto, 1Gb/s-full, 10Gb/s-full, ]
peer.sys.s1.p13.phy: { 'link-partner': { }, 'media': SFP-Plus-Empty, 'type': Ethernet, }
Am I missing something obvious here or is my backup unit broken?
... View more