Hello, i have appliance Firewall PA-460.
i do the testing power with this device. i had read the docs below.
Interpret the LEDs on a PA-400 Series Firewall (paloaltonetworks.com)
Replace a Power Adapter on a PA-400 Series Firewall (paloaltonetworks.com)
I had several test below.
1. Place 2 adapter connect to firewall, its working normally.
2. Disconnect 1 adapter from firewall. No alarm shows/LED, in cli show adapter not inserted
3. Place 2 Adapter, but disconnect 1 adapter from power source. No Alarm, then in cli still show adapter inserted.
as i test above, the conclusion is the firewall doesn't check the voltage as the docs says. but in the cli only show the adapter is inserted/not (even the adapter has no power).
But the question is, how we know if the firewall had a power in each adapter?
how to generate alarm if one of the adapter have no power? as the note below it says if the 2 adapter inserted and on adapter fail it will show the alarm, but as i test it not showing any error, in web ui or even in cli.
Thanks,
Denny
... View more