@rotra Good to hear that this has been resolved. For those of you in a similar situation, please remember that you must enable the setting "Dynamic URL Filtering" to access the BrightCloud database in the cloud for the latest categorization information. Otherwise, the URL filtering engine will only check for categorization on-device. If the specific URL you're looking for is not stored on the device, it will return category "unknown". Keep in mind that information is also cached on the device, so if you enable the dynamic URL filtering setting after you've started, you should use the "clear url-cache" command to clear the cache and force a cloud lookup for the latest categorization. Otherwise, you will use the cached category until that entry expires in the cache. Hope this helps, Doris