This website uses cookies essential to its operation, for analytics, and for personalized content. By continuing to browse this site, you acknowledge the use of cookies. For details on cookie usage on our site, read our Privacy Policy
The first time prior to define in Panorama new Template objects you must push the Template from Panorama to the devices with the flag "Force Template values" on (In Edit Selections) If you don´t do this the first time, all the Template (Network and Device) definitions in the device are marked as "Override" and then the prefered values in the push are the device values. Values on Override state : PREFERENCE DEVICE VALUES Values on No-Override State: panorama values Once you have values on No-Override State you must configure only from Panorama and Panorama values will be /the values on tehe device.
... View more
Hi guys, I´m trying to import in PanOS 4.1.11 a Customized Captive Portal Response Page and when I click on Import the result is a Dialog Box that says Please Wait and Uploading for ever and ever. Can somebody tell me how can I import this customized response Page? Is it a bug? When i imported a URL Filtering both Block and Continue / Override Page there was no problems, and them are correct. Thanks.
... View more
Hi, guys I have two Virtual Routers in a Virtual System in a 2050 Paloalto NGF version 3.1.12 I want to create a Static route in one of this Virtual Routers to send that traffic to the other Virtual Router similar like i do this in version 4.1. In version 4, when you add a static route there is a type of route "next VR" where you can define the other Virtual Route. In version 3 i can't find this type. Is not possible to define it in version 3? Best regards
... View more
Good morning I have a Virtual Wire configured on a PAN-2050 with Pan OS 3.1.8 and I connect in one Interface of it a Microsoft ISA Server 2004 and in the other interface a Catalyst Cisco Switch. This Microsoft ISA SERVER 2004 has a Microsoft Load Balancing Service (NLB) configured on it with another Microsoft ISA SERVER 2004 that is connected in other interface of the same switch. The Microsoft NLB Service in the ISA SERVER 2004 that is connected across the PAN-2050 VirtuallWire is down. If I connect this ISA SERVER directly to the same Catalyst Switch there is no problem with the NLB Service. Anybody Knows if there is any limitation in a VirtualWire PAN2050 (with PAN-OS 3.1.8) with a Server that has Microsoft NLB configured? There are any solution for this Problem? Best regards.
... View more