Hello,
For state of power source, ENTITY-STATE-MIB can be used.
ex. “snmpwalk -On -v2c -c public <ip> .1.3.6.1.2.1.131.1.1.1.ID*”
This oid shows state of power supply module and its alarm state “.1.3.6.1.2.1.131.1.1.1.3(EntityOperState).ID*” shows power state. 3(Active) is ,2(Idle = power is not coming)
“.1.3.6.1.2.1.131.1.1.1.4.ID*” shows alarm state as “major” when one of power supply does not get power.
Be mindful that PS Object ID(=ID* above) are different in models PA3260 uses 4 and 5 , PA5220 have 9 and 10 for PS1 and PS2 /PA7050 uses 39-42/PA7080 uses 34-41 , etc..
Best Regards,
Romain
... View more