HA A/P Failover - Interfaces not UP

L1 Bithead

Hi,

 

I am some what confused and reaching out for a little help.

 

We have a pair of 3020s in Active/Passive mode with two interfaces, DMZ (Ethernet1/1) & Public (Ethernet1/3). HA is configured to use dedicated HA Ports and all indicators on the dashboard are Matched and UP.

 

When I manually suspend the Active device, the Passive device becomes active and the indicators on the dashboard show that the Passive is now the primary (and CLI confirms) but the interfaces remain down. The suspended device interfaces go to a down state. As soon as I enable the suspended device the priority kicks in and the device becomes the Primary again and the interfaces become UP.

 

Does anyone have an idea?

 

___________________________________________________________

HA CONFIG:

Setup
Group ID: 33
Mode: active-passive

 

Active/Passive Settings
Passive Link State: shutdown (Active) | Auto (Passive)
Monitor Fail Hold Down Time (min): 1

 

Election Settings:

Device Priority: 10 (Active) | 110 (Passive)
Preemptive: Yes
Heartbeat Backup: Yes
HA Timer Settings: Recommended

 

Control Link (HA1): dedicated-ha1
Control Link (HA1 Backup): management
DataLink (HA2): dedicated-ha2 | Transport: Ethernet
DataLink (HA2 Backup): none

___________________________________________________________

 

Thank you,

 

Scott

Scott Menzies
1 accepted solution

Accepted Solutions

Cyber Elite
Cyber Elite

hi @SPS 

 

when you suspend the primary, does the secondary report it is active or non-funct?

are you sure the interfaces are cabled up properly, and the switch ports set up properly (have you tried switching out cables and switch ports and have you verified the switch ports have not been set to a down state)

Tom Piens
PANgurus - Strata specialist; config reviews, policy optimization

View solution in original post

2 REPLIES 2

Cyber Elite
Cyber Elite

hi @SPS 

 

when you suspend the primary, does the secondary report it is active or non-funct?

are you sure the interfaces are cabled up properly, and the switch ports set up properly (have you tried switching out cables and switch ports and have you verified the switch ports have not been set to a down state)

Tom Piens
PANgurus - Strata specialist; config reviews, policy optimization

I thought the passive interfaces were in a down state and displayed red in the PA console but that is only when the device is in a suspended or disconnected state.

 

I was over thinking things and didn't check the basics! I had put the switch ports into admin down whilst we moved ISPs and forgot to enable them again.

 

Thank you!

 

A very embarrassed Scott.

 

Scott Menzies
  • 1 accepted solution
  • 4579 Views
  • 2 replies
  • 0 Likes
Like what you see?

Show your appreciation!

Click Like if a post is helpful to you or if you just want to show your support.

Click Accept as Solution to acknowledge that the answer to your question has been provided.

The button appears next to the replies on topics you’ve started. The member who gave the solution and all future visitors to this topic will appreciate it!

These simple actions take just seconds of your time, but go a long way in showing appreciation for community members and the LIVEcommunity as a whole!

The LIVEcommunity thanks you for your participation!