- Access exclusive content
- Connect with peers
- Share your expertise
- Find support resources
Enhanced Security Measures in Place: To ensure a safer experience, we’ve implemented additional, temporary security measures for all users.
04-02-2019 06:51 PM
The office has 2 internet data line. Each of them has a fix public IP address. Device is a PA-820.
I want to separate the utilization of the data line as below.
1. Office area/staff primary use 1st data line. If this line down then auto change to use 2nd data line. When 1st data line resume. Auto change back.
2. Guest area always use 2nd data line.
What configuration can achieve this goal?
04-03-2019 07:42 AM
PBF is not dependant on the ZONEs could be IP/SUBNET/USER....
Rob
04-03-2019 08:33 PM
Hello,
I successful achieve this by using PBF and set different Metric number for the 2 interfaces in default route.
But found a problem. The 2nd interface (with higher metric number) cannot ping or being ping from outside. I think asymmetric ping was happen and look like it was caused by PBF.
04-04-2019 12:28 AM
Have you enabled PING in the interface management profile?
Rob
Click Accept as Solution to acknowledge that the answer to your question has been provided.
The button appears next to the replies on topics you’ve started. The member who gave the solution and all future visitors to this topic will appreciate it!
These simple actions take just seconds of your time, but go a long way in showing appreciation for community members and the LIVEcommunity as a whole!
The LIVEcommunity thanks you for your participation!