Not switch url-filtering vendor from brightcloud to pan-db in panos 6.0.0

cancel
Showing results for 
Show  only  | Search instead for 
Did you mean: 

Not switch url-filtering vendor from brightcloud to pan-db in panos 6.0.0

L4 Transporter

Hello

I tried to switch url-filtering vendor from brightcould to pan-db in panos 6.0.0 for test.

But it was not switched with the following error message.

I tried that fw reboot. but it was not still switched with same error message.

Please let me know resolved way.

Thanks.

switch url fitering vendors.png

1 accepted solution

Accepted Solutions

Hi Cheon,

The PAN box said you have to change HA state to suspend and then it's possible to change URL-DB

Bye.

Regards,

Roh

View solution in original post

4 REPLIES 4

L4 Transporter

Oops.

I mistake that a fw have HA configuration.

It is switched pan-db rul-filtering without problem after disable ha.

Hi Cheon,

The PAN box said you have to change HA state to suspend and then it's possible to change URL-DB

Bye.

Regards,

Roh

Hello Cheon,

This is an expected behavior. We need to bring the device into non-functional (in case of HA) in order to change the URL-DB.

Thanks

Thanks for the answer, Roh and HULK.

  • 1 accepted solution
  • 5917 Views
  • 4 replies
  • 0 Likes
Like what you see?

Show your appreciation!

Click Like if a post is helpful to you or if you just want to show your support.

Click Accept as Solution to acknowledge that the answer to your question has been provided.

The button appears next to the replies on topics you’ve started. The member who gave the solution and all future visitors to this topic will appreciate it!

These simple actions take just seconds of your time, but go a long way in showing appreciation for community members and the LIVEcommunity as a whole!

The LIVEcommunity thanks you for your participation!