04-15-2013 12:38 AM
Hi All,
I have an OP manager (network monitoring tool). I want to integrate it with Palo Alto. Does anyone have the OID for the CPU and OID for the memory of PA-2050?
Regards,
Eugene
04-15-2013 08:12 PM
Hi
I follow the guide but it is not successful. Does anyone have a new OID for the CPU and memory of PA-2050? thanks.
Regards,
Eugene
04-16-2013 05:03 AM
Management Plane CPU:1.3.6.1.2.1.25.3.3.1.2.1
Dataplane CPU 1.3.6.1.2.1.25.3.3.1.2.2
Click Accept as Solution to acknowledge that the answer to your question has been provided.
The button appears next to the replies on topics you’ve started. The member who gave the solution and all future visitors to this topic will appreciate it!
These simple actions take just seconds of your time, but go a long way in showing appreciation for community members and the LIVEcommunity as a whole!