this should work, but maybe try it like this:

 

in the profile, set the egress max to 1000 and then create a class4 (default) set to egress max 600

because all traffic is classified as class4 by default, the bw for all will be limited to 600, but it will allow you to easily make exceptions for other classes

Tom Piens
PANgurus - Strata specialist; config reviews, policy optimization

View solution in original post