04-08-2019 03:49 AM - edited 04-08-2019 09:35 AM
Hi,
After importing a ScreenOS configuration into Expedition 1.1.12, the dashboard shows 584 Addresses in Project Statistics.
But when going to Objects -> Address, only "No Address" is displayed in the left pane (despite I have "No Filters").
Does someone know what's wrong ?
Regards
04-10-2019 05:24 AM - edited 04-10-2019 05:25 AM
Forget about that, it was probably an encoding problem of the ScreenOS config file. The former config file was encoded in Windows-1252 (CP1252).
I have downloaded a new config file from the NetScreen, converted it to UTF-8 encoding and re-imported in Expedition, no more problems showing Addresses...
04-08-2019 11:49 AM
in the lower right hand corner, you will want to choose the "vsys 1" or "all" option along with the config file.
04-08-2019 02:03 PM
Thank you for your reply, already did it, but it does not solve the problem.
Thus I think I have found a begining of solution : some object names in my screenOS configuration file contains accented characters like "é è à ç..." (those are french words). I have substituted these characters in object names with their unaccented equivalent "e e a c...", then after reimporting the configuration file to a new project the dashboard now shoes 714 Address objects, and Adresses are listed in the Objects -> Address pane.
But when browsing all the Adresses objects list, at some page the pane becomes empty and the object count is reset to 0. Reloading the Objects -> Address pane and the Address objects reappears...
Seems like encoding problem regarding the configuration file, I am going to investigate further...
Does anybody know what are naming rules for Address objects (and perhaps other objects too) in PanOS ?
04-10-2019 05:24 AM - edited 04-10-2019 05:25 AM
Forget about that, it was probably an encoding problem of the ScreenOS config file. The former config file was encoded in Windows-1252 (CP1252).
I have downloaded a new config file from the NetScreen, converted it to UTF-8 encoding and re-imported in Expedition, no more problems showing Addresses...
Click Accept as Solution to acknowledge that the answer to your question has been provided.
The button appears next to the replies on topics you’ve started. The member who gave the solution and all future visitors to this topic will appreciate it!
These simple actions take just seconds of your time, but go a long way in showing appreciation for community members and the LIVEcommunity as a whole!
The LIVEcommunity thanks you for your participation!