06-29-2016 12:45 PM - edited 06-29-2016 02:23 PM
Hi,
I am working on multi-vsys (4) design with PA-7050 chassis. I would like to know if I can use aggregate interface over multiple vsys. I am thinking of using aggregate interface so that i can get link redundancy. The agg interface will have multiple sub-interfaces part of different vsys. Is it possible?
07-07-2016 07:55 AM
@pankaku - do you have multi-vsys enabled? I also checked it on PA-7050 but the default config too has a vsys associated for an interface. I was managed to get the sub-interfaces attached to different vsys however I could not get the base single/agg configured with no vsys. How did you do that?
07-07-2016 09:17 AM
Yes you can see the screenshot it is test on 5060 box.
07-07-2016 11:13 AM
@pankaku Can you please hit Edit for the interface and check the settings? Do you see no vsys under Agg interface? Here is what I see. Though the interface screen shows none for vsys, if you edit the interface it has vsys associated.
Click Accept as Solution to acknowledge that the answer to your question has been provided.
The button appears next to the replies on topics you’ve started. The member who gave the solution and all future visitors to this topic will appreciate it!
These simple actions take just seconds of your time, but go a long way in showing appreciation for community members and the LIVEcommunity as a whole!