Hi guys.
Nowadays I have got a project for installing PA7050 but I confused about the PA7050 how many security rule supported for PA7050. Several months ago, I checked the DataSheet and Compare tools of PA7050 that mentioned PA7050 supported 80,000 rules officially. For now the below link also mentioned that PA7050 can support 80,000 rules.
What is the Maximum Number of Rule Objects Supported?
However, For now compare tool showed that PA7050 supported only 40,000 rules and PA7050 box also said that supported 40,000 rule only via command "show system state | match policy".
What is correct capacity of rules for PA7050 box? Supported 80,000? or 40,000 only? Anybody knows about that issue? Please let me know correct answer.
Thanks.
Regards,
Roh
04-10-2015 08:31 AM
Hello Roh,
From the spec sheet of 7050 and also the output of 'show system state | match policy' with latest panos version it shows 40,000 rules only.
Click on 'show more' under 7050
cfg.general.max-policy-rule: 40000
Hope that helps.
-Dileep