03-25-2011 12:31 AM
03-25-2011 03:02 AM
Hello,
what kind of CLI Role have you selected when defining the role?
You can check this when editing the role in question; try to set it to superuser or superreader, if it's disabled right now.
It works in our setup with 3.1.7.
Edit: Sorry, just read now that you're using Panorama. Might still be helpful, though.
Message was edited by: stefanhager
03-28-2011 06:11 PM
Hello stefanhager,
Thank you for your reply.
Yes, this issue is on Panorama.
Of couse, the CLI Role is set to 'superuser'.
Device or Vsys admin are able to enter their webUI,
but they are not able to enter their CLI on Panroama.
And for example, we have no way of getting a debug of PA-device on Panorama.
- the only way to enter the PA-device directly.
Thank you,
Tomoyuki Komure
Click Accept as Solution to acknowledge that the answer to your question has been provided.