PA-5000 Series Disk hot swap?

cancel
Showing results for 
Show  only  | Search instead for 
Did you mean: 
Announcements

PA-5000 Series Disk hot swap?

L3 Networker

Hello~~

I am very curious,,

It is simple question

as far as we know, PA-5000 Series can install RAID 1 Disk

If PA failed either disks

Can PA continue logging another disk?

If so

When failed disk exchange, Does have to reboot PA?

I am extremely confused now

I had not found document on Support Site yet

Would someone like to find document?

1 accepted solution

Accepted Solutions

L5 Sessionator

PA will continue logging to the second disk if the first one fails.

Please refer the following document which talks about upgrade/swap procedure:-

https://live.paloaltonetworks.com/docs/DOC-1926

View solution in original post

3 REPLIES 3

L5 Sessionator

PA will continue logging to the second disk if the first one fails.

Please refer the following document which talks about upgrade/swap procedure:-

https://live.paloaltonetworks.com/docs/DOC-1926

Thank you for your answer

I have more question~

if so

There are two PA Devices as HA environment

suddenly, If one of them failed Disk without RAID 1

Active move other device?

If the disk fails it should failover to the other device.

Secondly it is recommended that both the devices have the same number of SSD's.

  • 1 accepted solution
  • 2898 Views
  • 3 replies
  • 0 Likes
Like what you see?

Show your appreciation!

Click Like if a post is helpful to you or if you just want to show your support.

Click Accept as Solution to acknowledge that the answer to your question has been provided.

The button appears next to the replies on topics you’ve started. The member who gave the solution and all future visitors to this topic will appreciate it!

These simple actions take just seconds of your time, but go a long way in showing appreciation for community members and the LIVEcommunity as a whole!

The LIVEcommunity thanks you for your participation!