06-28-2017 02:49 AM
Hi All,
Weird one! HA pair 3020. The initial issue was that the action was not able to sync to passive. Attempted to restart the mgmt server, no changes. Attempted to restart the dataplane, received GUI error saying you can only restart the box manually. Manual restart didn't make any difference. Show interfaces all shows no interfaces on the device:
RMA?
Thx,
Myky
06-29-2017 04:12 PM
Heys,
This was something to do with content update crash. Commit force was giving the following error:
So after the reboot device was not able to complete auto commit. 710 was the app&threat release. TAC did try multiple options in order to recover the device, but with no avail. The decision was made to factory reset the unit and that did a trick.
Thx,
Myky
06-29-2017 04:01 AM
sounds like a candidate for RMA, have you opened a support case ? please share the outcome 🙂
06-29-2017 04:12 PM
Heys,
This was something to do with content update crash. Commit force was giving the following error:
So after the reboot device was not able to complete auto commit. 710 was the app&threat release. TAC did try multiple options in order to recover the device, but with no avail. The decision was made to factory reset the unit and that did a trick.
Thx,
Myky
Click Accept as Solution to acknowledge that the answer to your question has been provided.
The button appears next to the replies on topics you’ve started. The member who gave the solution and all future visitors to this topic will appreciate it!
These simple actions take just seconds of your time, but go a long way in showing appreciation for community members and the LIVEcommunity as a whole!
The LIVEcommunity thanks you for your participation!