03-30-2026 03:32 AM - edited 03-30-2026 03:56 AM
Thank you for your continued support.
Please allow me to confirm the following.
① The PA-400 and PA-500 series do not have HA ports. However, we are assuming that the regular ports will be used as HA ports.
In that case, are two HA ports required? Currently, we are using 8 ports (1 port for HA), so we understand that a device with 9 or more ports will be necessary. In that case, we anticipate the following to be the minimum configuration. Is there any discrepancy in our understanding?
400 series: PA-415 or PA-445
500 series: PA-550
② Regarding the PA-415 and PA-445, four ports are listed as RJ45/PoE ports. Even when using them for IPS purposes, we do not anticipate any impact from using the PoE ports. Is there any discrepancy in our understanding?
05-13-2026 05:47 AM - edited 05-13-2026 05:49 AM
1. You only really need 1 dataplane port for HA2 as the management port can be used as the primary HA1, although it is recommended to use an additional dataplane port as HA1-b
2. the PoE ports simply have the capacity to supply power to an external device (mini switch, camera,...) while also providing ethernet connectivity. you are not required to enable PoE so can use those interfaces as regular ports
Click Accept as Solution to acknowledge that the answer to your question has been provided.
The button appears next to the replies on topics you’ve started. The member who gave the solution and all future visitors to this topic will appreciate it!
These simple actions take just seconds of your time, but go a long way in showing appreciation for community members and the LIVEcommunity as a whole!
The LIVEcommunity thanks you for your participation!