07-05-2016 09:56 PM - edited 07-05-2016 10:04 PM
Hello,
How do I verify if an interface status changed by date and time? Example: I would like to know if Ethernet1/10 went down last week or 2 days ago at a 10:00 am.
Thanks for any help.
07-05-2016 11:52 PM
Hi,
Command below:
> show log system subtype equal port
07-06-2016 01:24 AM
If you want to apply time frame also to command, you can try below:
show log system subtype equal port direction equal backward receive_time in last-7-days
More time options under this command:
last-12-hrs last-12-hrs
last-15-minutes last-15-minutes
last-24-hrs last-24-hrs
last-30-days last-30-days
last-6-hrs last-6-hrs
last-60-seconds last-60-seconds
last-7-days last-7-days
last-calendar-day last-calendar-day
last-calendar-month last-calendar-month
last-hour last-hour
You can also specify custom time frame also.