- Access exclusive content
- Connect with peers
- Share your expertise
- Find support resources
Enhanced Security Measures in Place: To ensure a safer experience, we’ve implemented additional, temporary security measures for all users.
06-07-2022 12:23 AM
PA850 high Temperature long time, I see system log Alarm on Power Suuply #1 and Uptime is renew. I don't know why uptime is renew.
06-07-2022 07:38 PM - edited 06-07-2022 07:38 PM
Hi @BaNk ,
Please enter the command "show system environmentals". This command will tell us whether the alarm is true or false. If true try the following:
1. Reseat the power supply
2. Replace the power chord
3. Plug into a different power source
Check the output of "show system environmentals", "show log system", "less mp-log ehmon.log", and "less mp-log chasd.log" for further detection of a faulty PSU/fans. If there is further indication, please submit an RMA request with support.
Click Accept as Solution to acknowledge that the answer to your question has been provided.
The button appears next to the replies on topics you’ve started. The member who gave the solution and all future visitors to this topic will appreciate it!
These simple actions take just seconds of your time, but go a long way in showing appreciation for community members and the LIVEcommunity as a whole!
The LIVEcommunity thanks you for your participation!