05-28-2024 12:55 PM
Hi all,
I created an AutoIt script, and the steps are working as required. However, if the user tries to interfere with it, they are successful. For example, if the user keeps a key pressed down during the entire process, they key is also sent to the username and password fields when they come into focus during the "Send()" instruction.
How can we block such interference?
The documentation says that interference is blocked by default until the SendPID() instruction is carried out, but my Send() commands are before the PSMGenericClient_SendPID() command and user can still interfere.
I'm trying to understand what the "Lock Application Window" section does, but the documentation does not exactly explain it in human terms. Apart from this, is seems like it is only relevant if the CC is NOT a remote app (eg. https://community.cyberark.com/s/question/0D52J00009Y1j2zSAB). I tested with both DisableRemoteApp and without, to no avail.
I also tried explicitly adding BlockUserInput=Yes under "Target Settings > Client Specific" to no avail.
Might someone from the community have a clue?
(PSM v12.6.7.5, if it makes a significant difference).
05-30-2024 09:15 AM
Ah, bit of a gotcha - PSM cannot run a connector as administrator, as per https://community.cyberark.com/s/question/0D52J00006tr1l1SAA/psm-custom-cc-with-autoit-how-to-handle-consoles-which-need-elevated-permissions
05-28-2024 04:07 PM
Hi @Steven Sultana
AutoIt provides the BlockInput() function to block user input (mouse and keyboard) during critical parts of the script. You can enable this before your Send() commands and disable it afterward.
You can find more information about this function on AutoIT site.
Hope it helps !
05-29-2024 12:09 AM
Thank you for the suggestion. Unfortunately, with BlockInput(1) I'm still able to interfere. I'm running the script from the PSM server itself: "autoit.exe script.au3 components_dir /test" (with the proper full paths where necessary). I did this to ensure that whatever I messed with in the CC does not end up causing issues due to conflicts etc.
05-29-2024 05:39 PM
Hi @Steven Sultana
If you are using modal message box in the AutoIt script, please try excluding it.
The message box can cause the script to pause and potentially allowing user input to interfere.
05-30-2024 12:20 AM
My apologies, I did not report my findings!
It seems like "RequireAdmin" keyword is needed at the top of the script for BlockInput() to work as required.
05-30-2024 09:15 AM
Ah, bit of a gotcha - PSM cannot run a connector as administrator, as per https://community.cyberark.com/s/question/0D52J00006tr1l1SAA/psm-custom-cc-with-autoit-how-to-handle-consoles-which-need-elevated-permissions