Hi everyone,
I'm having a bit of trouble configuring link aggregation between my PA-5050 and Juniper EX4500 switches over 10G interfaces. The problem seems to stem from the fact that the PA-5050 link-aggregation dialog gives two options for link speed: 1000 or Auto, whereas the EX4500 configuration requires a hardcoded 10G speed setting.
How can I tell the PA-5050 to use a speed of 10000 instead of Auto?
11-22-2013 08:15 AM
Hello Mack,
According to the following document, its by design that we have to set the speed to Auto for 10G interfaces:
No 10gb (10000) Speed Option in GUI
Hope that helps!
Thanks and regards,
Kunal Adak
11-22-2013 08:15 AM
Hello Mack,
Can you try the below command and see how it works for you,
configure
set network interface ethernet ethernet1/x link-speed 10000
commit
Thanks
11-22-2013 08:15 AM
Hello Mack,
According to the following document, its by design that we have to set the speed to Auto for 10G interfaces:
No 10gb (10000) Speed Option in GUI
Hope that helps!
Thanks and regards,
Kunal Adak
11-22-2013 08:21 AM
Hello Mack,
To add more to better understand on capability, pls refer the below doc.
Commit Error: Invalid Forced Speed/Duplex for Ethernet1/x
Thanks