Hello guys,
We recently tried to upgrade our Panorama from version 5.1.5 to version 6.0. The upgrade itself was okay, but we were unable to do commits to devices still running v5.x afterwards. It looks like it's related to custom application signatures we created in Panorama and pushed to the devices.
The error message we got was:
Before the upgrade there was an additional checkbox in the "Scanning" section named "Spyware". However, that checkbox was NOT checked before the upgrade...
Any advise what we could do to fix this issue?
Thanks!
Oliver
03-30-2014 01:35 AM
you can export the candidate configuration and open it with an editor
Then delete spyware-ident section from the config
save it with a different name
upload the config.And you will be able to commit.
03-30-2014 01:35 AM
you can export the candidate configuration and open it with an editor
Then delete spyware-ident section from the config
save it with a different name
upload the config.And you will be able to commit.
03-30-2014 02:36 AM
Thank you. We'll try that next time we upgrade. We had to revert back to v5.1.5 because of this error.
Am I correct that it's otherwise basically supported to manage PAN-OS 5 devices with Panorama v6.0 ?
03-30-2014 02:38 AM
yes you can manage devices with 5.0 from 6.0 panorama
03-30-2014 04:18 AM
I just tried what you suggested and it worked like a charm. Thanks a lot for your help!
Click Accept as Solution to acknowledge that the answer to your question has been provided.
The button appears next to the replies on topics you’ve started. The member who gave the solution and all future visitors to this topic will appreciate it!
These simple actions take just seconds of your time, but go a long way in showing appreciation for community members and the LIVEcommunity as a whole!
The LIVEcommunity thanks you for your participation!