03-16-2012 09:51 AM
hello friends....
I have a PA-20-50 configured as content filtering and is synchronized with a pan-agent, the problem I have is that the device is completely disconnected after 10 minutes and only restarting again operate.
Know if any physical detail or firmware version, because neither the administration interface responds.
Device:PA-2050
Firmware:3.1.11
the records do not show me something to tell me the possible failure.
regards!!!!!!!
03-16-2012 11:08 AM
is correct, after I reboot the device is operating normally for an average of 10 min, but the fault is constant because the communication is lost again by all means for the same period of time on average.
Greetings!!
03-16-2012 11:23 AM
Can you ping and connect via SSH to the mgmt IP when this happen?
03-20-2012 09:06 AM
hello, I could solve the problem, problem was the port speed of administration.
thanks and Greetings!!