Hello guys,
I have made a stupid mistake on a PA-820. I have changed the Permitted IP in the Interface Management Settings to a single IP (the Panorama server) and now I cannot access the device anymore.
Any ideas? I cannot access even in SSH. The Pan-OS versionis 8.0.3 and is peered with another device (that I can access).
Thanks
11-30-2017 04:59 AM - edited 11-30-2017 04:59 AM
Hi @Shye80
You've got two options.
Connect to the device using a console cable and remove the permitted IP configuration on the CLI.
Connect up a client to the network and give it Panorama's IP address. Pretty risky this one though as you'd have to shut down Panorama or change it's IP which could impact your PAN deployment if you're logging and making changes etc on it.
hope this helps,
Ben
11-30-2017 05:18 AM
Hello Ben,
many thanks for you reply. I simply fixed connecting from the Panorama CLI to the device via SSH and changed the permitted IP with the command "delete deviceconfig system permitted-ip" and "set deviceconfig system permitted-ip".
Thank you