HA 1 Connection down - in M200

L2 Linker

Hi community,

 

In our Panorama M-200 appliance we are seeing HA1 Connection down system logs for HA. I am unable to see any interface details in the panorama, Kindly help me troubleshoot in this case.

 

suba_muthuram_0-1677560670237.png

 

suba
1 accepted solution

Accepted Solutions

Cyber Elite
Cyber Elite

Hello @suba_muthuram

 

as a next step, I would go through logs in CLI:

 

less mp-log ha_agent.log

less mp-log ms.log

 

Based on time stamps, it looks like that HA breaking happens regularly in 2 hours 15 minutes intervals. What is the infrastructure between both M-200 appliances? Is there any high volume traffic at regular intervals to saturate links to cause HA heartbeat to fail?

 

Kind Regards

Pavel

Help the community: Like helpful comments and mark solutions.

View solution in original post

7 REPLIES 7

L4 Transporter

Hello @suba_muthuram 

 

This is very strange, are you sure it is your M-200 log? Surely they are not logs from some firewall to manage with your PANORAMA M-200, since PANORAMA M-200 does not have an HA1 interface... firewalls do, but PANORAMA M-200 does not... for Panorama's HA, you use the MGT interface.

 

Check your logs well, I think it's something from your firewalls.

 

Greetings

High Sticker

L2 Linker

Hi @Metgatz ,

 

This is from Panorama only. I have verified the serial number it is for panorama only. 

 

suba

Cyber Elite
Cyber Elite

Hello @suba_muthuram

 

as a next step, I would go through logs in CLI:

 

less mp-log ha_agent.log

less mp-log ms.log

 

Based on time stamps, it looks like that HA breaking happens regularly in 2 hours 15 minutes intervals. What is the infrastructure between both M-200 appliances? Is there any high volume traffic at regular intervals to saturate links to cause HA heartbeat to fail?

 

Kind Regards

Pavel

Help the community: Like helpful comments and mark solutions.

L0 Member

Was there any resolution to this issue?   We are seeing the same behavior right after an upgrade from 9.1-13 to 10.1.9

Yes, It was our environment we have wan connectivity between both M-200 appliance and the timer also aggressive it is 2secs for heart beat interval. 

suba

What did you set the timer to?

L0 Member

Was this resolved? I have the same issue on M600, hold time timer has been changed from 3000ms to 60000ms, still the same.

  • 1 accepted solution
  • 3114 Views
  • 7 replies
  • 0 Likes
Like what you see?

Show your appreciation!

Click Like if a post is helpful to you or if you just want to show your support.

Click Accept as Solution to acknowledge that the answer to your question has been provided.

The button appears next to the replies on topics you’ve started. The member who gave the solution and all future visitors to this topic will appreciate it!

These simple actions take just seconds of your time, but go a long way in showing appreciation for community members and the LIVEcommunity as a whole!

The LIVEcommunity thanks you for your participation!