12-21-2017 04:43 AM
Hi,
I have a case where we have to PA FWs and there is 3 connections between them,
1- Two Microwave Links (Up to 100mbps)
2- One DSP Link (Up to 10mbps)
There is a total of 3 IPSec Tunnels and i'm using weighted round robin, however, i don't know how to calculate the weights and what numbers i should put in the ECMP to reflect the real speeds of the links.
12-21-2017 05:18 PM
The weights are simply relative to each other with higher being better (up to 255). So in your case I would simply use 100 and 10 as the values matching the bandwidth of the circuits.
12-21-2017 05:18 PM
The weights are simply relative to each other with higher being better (up to 255). So in your case I would simply use 100 and 10 as the values matching the bandwidth of the circuits.