03-21-2017 12:00 AM - edited 03-22-2017 01:52 AM
is it possible to monitor through SNMP oids for Fan failures in PA 200, PA 500 and PA 5050.
Should we use different oid for each platforms.
04-03-2017 05:57 AM - edited 04-03-2017 05:58 AM
Does any one uses OID for this in SNMP. I want mainly for PAN 200 and PA 500
04-05-2017 02:16 AM
You can walk the ENTITY-SENSOR-MIB at the firewall look for the entPhySensorOperStatus values; compare the result with a walk for the variable entPhySensorType; the ones resulting in rpm will be a FAN; hence the corresponding entPhySensorOperStatus variables will give their status.
M.
04-18-2017 10:56 PM
I could not find the option mentioned here.
I am checking here. Can anyone guide me.
04-27-2017 07:00 AM
Can you tell me where this option in my screenshot above