07-17-2022 11:59 PM
Is there any pre-requisite to keep the interface speed and duplex to auto , auto if we are using them in HA Link Monitoring?
During our HA Test our PA interfaces are kept in duplex auto , speed 1000 setting , we have shutdown the switch interface , PA has detected that that interface is down ( forced down) but it's not triggering the failover , when we set the speed to auto ..it has triggered the failover.
07-19-2022 09:00 AM
Hello,
Might want to reach out to support to see if they have anything.
Regards,
07-18-2022 01:09 PM
Hello,
Not sure if its a requirement, however I recommend to keep it auto/auto unless there is a dire need not to (i.e. an ISP link that is hard set).
Regards,
07-18-2022 07:52 PM
Thank you for your kind response, it would be nice if I can find an official document. I have researched a bit but nowhere does it mentions about speed and duplex settings.
07-19-2022 09:00 AM
Hello,
Might want to reach out to support to see if they have anything.
Regards,
Click Accept as Solution to acknowledge that the answer to your question has been provided.
The button appears next to the replies on topics you’ve started. The member who gave the solution and all future visitors to this topic will appreciate it!
These simple actions take just seconds of your time, but go a long way in showing appreciation for community members and the LIVEcommunity as a whole!