09-05-2017 04:31 AM
Has anyone out there experienced this?
name id speed/duplex/state mac address
--------------------------------------------------------------------------------
ethernet1/1 64 10000/full/up 58:49:3b:fb:72:40
ethernet1/2 65 10000/full/up 58:49:3b:fb:72:41
ethernet1/3 66 ukn/ukn/down(disabled) b4:0c:25:e0:40:42
We have installed a new Finistar SFP+ (FTLX8574D3BCL), which according to the documentation is compatible with PA-7050.
The IP assigned to the interface cannot be pinged.
What can I do to troubleshoot this phenomene?
Regards,
Jasper Freeman
09-13-2017 01:02 AM
The solution to the problem was:
Check the switch interface on which the logcard is connected.
The on the switch interface was set to 1000 und should be 10000.
09-05-2017 05:57 AM - edited 09-05-2017 05:57 AM
Hi Jasper
it looks like the interface has been set as 'down' manually
make sure the link state is set to auto or up:
09-13-2017 01:02 AM
The solution to the problem was:
Check the switch interface on which the logcard is connected.
The on the switch interface was set to 1000 und should be 10000.