07-19-2011 08:19 PM
Hi All
I got an issue with PA-500 alarm-led is light and when I debug with cli and someing shown fllowing.
>show log system severity equal critical
2011/07/19 10:01:22critical general general 0 Chassis Master Alarm: Temperature
2011/07/19 20:10:22critical general general 0 Chassis Master Alarm: Cleared
2011/07/19 20:16:22critical general general 0 Chassis Master Alarm: Temperature
2011/07/19 20:19:22critical general general 0 Chassis Master Alarm: Cleared
2011/07/19 20:23:22critical general general 0 Chassis Master Alarm: Temperature
2011/07/19 20:26:22critical general general 0 Chassis Master Alarm: Cleared
2011/07/20 09:33:22critical general general 0 Chassis Master Alarm: Temperature
2011/07/20 09:42:22critical general general 0 Chassis Master Alarm: Cleared
Would anyone can tell me what the mane massage show is?
thanks.
-joy
07-20-2011 12:15 AM
Your Temperature is/was at a threshold value.
Try to check with:
show system environmentals
show system state | match chassis.alarm
Click Accept as Solution to acknowledge that the answer to your question has been provided.
The button appears next to the replies on topics you’ve started. The member who gave the solution and all future visitors to this topic will appreciate it!
These simple actions take just seconds of your time, but go a long way in showing appreciation for community members and the LIVEcommunity as a whole!