Hello,

We use vsys on our PaloAlto cluster. During a new vsys deployment, I would like to validate that the passive device's physical connectivity to a switch is working.

But I don't wish to launch a failover just for this, because it could impact the whole cluster.

Is there any way to test physical or logical interfaces connectivity without any failover ?

Emmanuel

1 accepted solution

Accepted Solutions

L6 Presenter

If you're running PAN-OS 4.1 or prior, you can set the HA passive link state to auto for L3 deployment,  This will allow for the Ethernet links to be up if connected to a switch. 

Starting in PAN-OS 5.0, you can set the HA passive link state to auto for L3 and vwire modes.

Thanks.

View solution in original post

2 REPLIES 2

L6 Presenter

If you're running PAN-OS 4.1 or prior, you can set the HA passive link state to auto for L3 deployment,  This will allow for the Ethernet links to be up if connected to a switch. 

Starting in PAN-OS 5.0, you can set the HA passive link state to auto for L3 and vwire modes.

Thanks.

Many thanks for these useful information !

Best Regards

Emmanuel

  • 1 accepted solution
  • 3564 Views
  • 2 replies
  • 0 Likes
Like what you see?

Show your appreciation!

Click Like if a post is helpful to you or if you just want to show your support.

Click Accept as Solution to acknowledge that the answer to your question has been provided.

The button appears next to the replies on topics you’ve started. The member who gave the solution and all future visitors to this topic will appreciate it!

These simple actions take just seconds of your time, but go a long way in showing appreciation for community members and the LIVEcommunity as a whole!

The LIVEcommunity thanks you for your participation!