04-24-2024 01:03 PM
Good afternoon,
I am having trouble with connecting to this fleet 3 dashboard, with GP. It appears to be a a DNS issue, because it will find the local network when GP is disabled. The virtual adapter takes over, and uses our DNS server, so it is not on a local network at that point. I have tried changing the DNS addresses, in the adpater and in GP, and it did not fix the issue. Thanks for any help.
Luke
04-26-2024 01:05 AM
Hi @LukePowell ,
Sounds like your GP is configured to not allow split tunneling and send all traffic inside the tunnel.
Ask your admin to check the GP gateway configuration at Network > GlobalProtect > Gateways > Agent > Client Settings > Split Tunnel
Hope this helps,
-Kim.
10-08-2024 06:27 AM
wanted to share that when the axon body cameras are plugged back into the laptops to upload the data, they create a new network adapter. we tried split tunneling but lack of documentation from axon and their support didn't help.
ended up doing a process based split tunnel for just for a specific user-id group that was using them with the 3 processes
axon fleet.exe, axon-agent.exe, axon evidence upload xt v2.exe
Click Accept as Solution to acknowledge that the answer to your question has been provided.
The button appears next to the replies on topics you’ve started. The member who gave the solution and all future visitors to this topic will appreciate it!
These simple actions take just seconds of your time, but go a long way in showing appreciation for community members and the LIVEcommunity as a whole!