Console conection using CISCO terminal server

cancel
Showing results for 
Show  only  | Search instead for 
Did you mean: 
Announcements
Please sign in to see details of an important advisory in our Customer Advisories area.

Console conection using CISCO terminal server

Hi

 

First of all i would like to say that im able to conect with serial cable to the Console Port with my laptop.

 

The issue only occurs when i try to conect to the Console port via Cisco Terminal controller (TTY)

At the begining i thought was a problem with the values that Palo Alto recomend for this kind of conection (see below)

 

Bits per sec    :  9600

Data bits       :     8

Parity          :  none

Stop bits       :     1

Flow control    :  none

 

But after check and as you can see on below ouput the TTY that i use on the Cisco Device is with Values

 

show line tty 6
Tty Line Typ Tx/Rx A Modem Roty AccO AccI Uses Noise Overruns Int
0/0/4 6 TTY 9600/9600 - - - - - 0 0 0/0 -

Line 0/0/4, Location: "", Type: ""
Length: 24 lines, Width: 80 columns
Baud rate (TX/RX) is 9600/9600, no parity, 1 stopbits, 8 databits
Status: Ready
Capabilities: EXEC Suppressed
Modem state: Ready
Modem hardware state: noCTS noDSR DTR noRTS
Special Chars: Escape Hold Stop Start Disconnect Activation
BREAK none - - none
Timeouts: Idle EXEC Idle Session Modem Answer Session Dispatch
never 02:00:00 none not set
Idle Session Disconnect Warning
never
Login-sequence User Response
00:00:30
Autoselect Initial Wait
not set
Modem type is unknown.
Session limit is not set.
Time since activation: never
Editing is enabled.
History is enabled, history size is 20.
DNS resolution in show commands is enabled
Full user help is disabled
Allowed input transports are pad telnet rlogin lapb-ta mop udptn v120 ssh.
Allowed output transports are pad telnet rlogin lapb-ta mop v120 ssh.
Preferred transport is telnet.
Shell: enabled
Shell trace: off
No output characters are padded
No special data dispatching characters

 

1 accepted solution

Accepted Solutions

L7 Applicator

Generally these terminal servers use RJ45 flip cables as the connection from the terminal server port to the port on the device and not ethernet cables.  But many also have custom pin out arrangements as well.  You should look up the cable requirements of your model device and confirm what you have is correct.

Steve Puluka BSEET - IP Architect - DQE Communications (Metro Ethernet/ISP)
ACE PanOS 6; ACE PanOS 7; ASE 3.0; PSE 7.0 Foundations & Associate in Platform; Cyber Security; Data Center

View solution in original post

1 REPLY 1

L7 Applicator

Generally these terminal servers use RJ45 flip cables as the connection from the terminal server port to the port on the device and not ethernet cables.  But many also have custom pin out arrangements as well.  You should look up the cable requirements of your model device and confirm what you have is correct.

Steve Puluka BSEET - IP Architect - DQE Communications (Metro Ethernet/ISP)
ACE PanOS 6; ACE PanOS 7; ASE 3.0; PSE 7.0 Foundations & Associate in Platform; Cyber Security; Data Center
  • 1 accepted solution
  • 2720 Views
  • 1 replies
  • 0 Likes
Like what you see?

Show your appreciation!

Click Like if a post is helpful to you or if you just want to show your support.

Click Accept as Solution to acknowledge that the answer to your question has been provided.

The button appears next to the replies on topics you’ve started. The member who gave the solution and all future visitors to this topic will appreciate it!

These simple actions take just seconds of your time, but go a long way in showing appreciation for community members and the LIVEcommunity as a whole!

The LIVEcommunity thanks you for your participation!