Link and path monitoring enabled but no link and path group configured

cancel
Showing results for 
Show  only  | Search instead for 
Did you mean: 
Announcements
Please sign in to see details of an important advisory in our Customer Advisories area.

Link and path monitoring enabled but no link and path group configured

L2 Linker

Hi All,

 

We have Link and path monitoring enabled but no link and path group configured.

 

Actually I never enabled the link and path monitoring so my question is , is it enabled by default?

 

Also, if we don't have any link or path group configured as in my case, is it not active ?

 

I could not find any doc for the same.  

 

@BPry  Can you please help me on this or anyone ? Thanks

1 accepted solution

Accepted Solutions

Community Team Member

Hi @shafi021 ,

 

It actually says so in the appliance help pages:

 

"Enable and configure either path monitoring or link monitoring to help trigger a failover if a path or link goes down. Configure at least one Path Group for path monitoring and configure at least one Link Group for Link Monitoring."

 

Hope this helps.

-Kiwi.

 

 

LIVEcommunity team member, CISSP
Cheers,
Kiwi
Please help out other users and “Accept as Solution” if a post helps solve your problem !

Read more about how and why to accept solutions.

View solution in original post

3 REPLIES 3

Community Team Member

Hi @shafi021 ,

 

I believe it was discussed here as well:

https://live.paloaltonetworks.com/t5/general-topics/ha-link-monitoring/td-p/306595

 

Basically you'll need to configure at least one Path Group for path monitoring and configure at least one Link Group for Link Monitoring.

 

No interfaces will be monitored if you don't put any in the Link Group.

 

Hope this helps !

-Kiwi.

LIVEcommunity team member, CISSP
Cheers,
Kiwi
Please help out other users and “Accept as Solution” if a post helps solve your problem !

Read more about how and why to accept solutions.

Thank you Kiwi for the reply. I read the post but there is no document on this. I was hoping to see it in some Doc. Thanks

Community Team Member

Hi @shafi021 ,

 

It actually says so in the appliance help pages:

 

"Enable and configure either path monitoring or link monitoring to help trigger a failover if a path or link goes down. Configure at least one Path Group for path monitoring and configure at least one Link Group for Link Monitoring."

 

Hope this helps.

-Kiwi.

 

 

LIVEcommunity team member, CISSP
Cheers,
Kiwi
Please help out other users and “Accept as Solution” if a post helps solve your problem !

Read more about how and why to accept solutions.
  • 1 accepted solution
  • 3255 Views
  • 3 replies
  • 0 Likes
Like what you see?

Show your appreciation!

Click Like if a post is helpful to you or if you just want to show your support.

Click Accept as Solution to acknowledge that the answer to your question has been provided.

The button appears next to the replies on topics you’ve started. The member who gave the solution and all future visitors to this topic will appreciate it!

These simple actions take just seconds of your time, but go a long way in showing appreciation for community members and the LIVEcommunity as a whole!

The LIVEcommunity thanks you for your participation!