11-15-2020 03:12 PM
Service object limits were raised on the PA-5200 and PA-3200 series with PAN-OS 9.0 so you'd need to upgrade to a 5220 as long as the PA-5020 was working properly for everything else which would upgrade you to a 8,000 service object limit.
Personally, I would go through your configuration and see why you need to have 2000 service objects configured. Could you get rid of some of your services and switch to app-id policies where you could utilize application-default, or are you making really specific service objects that could be re-used if you renamed them to something more generic?